Pregnant women models analyzed for RF exposure and temperature increase in 3T RF shimmed birdcages. Issue 5 (May 2017)
- Record Type:
- Journal Article
- Title:
- Pregnant women models analyzed for RF exposure and temperature increase in 3T RF shimmed birdcages. Issue 5 (May 2017)
- Main Title:
- Pregnant women models analyzed for RF exposure and temperature increase in 3T RF shimmed birdcages
- Authors:
- Murbach, Manuel
Neufeld, Esra
Samaras, Theodoros
Córcoles, Juan
Robb, Fraser J.
Kainz, Wolfgang
Kuster, Niels - Abstract:
- Abstract : Purpose: MRI is increasingly used to scan pregnant patients. We investigated the effect of 3 Tesla (T) two‐port radiofrequency (RF) shimming in anatomical pregnant women models. Theory and Methods: RF shimming improves B1 + uniformity, but may at the same time significantly alter the induced current distribution and result in large changes in both the level and location of the absorbed RF energy. In this study, we evaluated the electrothermal exposure of pregnant women in the third, seventh, and ninth month of gestation at various imaging landmarks in RF body coils, including modes with RF shimming. Results: Although RF shimmed configurations may lower the local RF exposure for the mother, they can increase the thermal load on the fetus. In worst‐case configurations, whole‐body exposure and local peak temperatures—up to 40.8°C—are equal in fetus and mother. Conclusions: Two‐port RF shimming can significantly increase the fetal exposure in pregnant women, requiring further research to derive a very robust safety management. For the time being, restriction to the CP mode, which reduces fetal SAR exposure compared with linear‐horizontal polarization modes, may be advisable. Results from this study do not support scanning pregnant patients above the normal operating mode. Magn Reson Med 77:1–1, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- Is Part Of:
- Magnetic resonance in medicine. Volume 77:Issue 5(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 77:Issue 5(2017)
- Issue Display:
- Volume 77, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 5
- Issue Sort Value:
- 2017-0077-0005-0000
- Page Start:
- C1
- Page End:
- C1
- Publication Date:
- 2017-05
- Subjects:
- MRI safety -- SAR -- RF shimming performance -- Virtual Population -- thermoregulation
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26425 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 812.xml