A novel adaptive discrete cosine transform‐domain filter for gap‐inpainting of high resolution PET scanners. Issue 8 (30th November 2016)
- Record Type:
- Journal Article
- Title:
- A novel adaptive discrete cosine transform‐domain filter for gap‐inpainting of high resolution PET scanners. Issue 8 (30th November 2016)
- Main Title:
- A novel adaptive discrete cosine transform‐domain filter for gap‐inpainting of high resolution PET scanners
- Authors:
- Shih, Cheng‐Ting
Wu, Jay
Lin, Hsin‐Hon
Chang, Shu‐Jun
Chuang, Keh‐Shih - Abstract:
- Abstract : Purpose: Several positron emission tomography (PET) scanners with special detector block arrangements have been developed in recent years to improve the resolution of PET images. However, the discontinuous detector blocks cause gaps in the sinogram. This study proposes an adaptive discrete cosine transform‐based (aDCT) filter for gap‐inpainting. Methods: The gap‐corrupted sinogram was morphologically closed and subsequently converted to the DCT domain. A certain number of the largest coefficients in the DCT spectrum were identified to determine the low‐frequency preservation region. The weighting factors for the remaining coefficients were determined by an exponential weighting function. The aDCT filter was constructed and applied to two digital phantoms and a simulated phantom introduced with various levels of noise. Results: For the Shepp‐Logan head phantom, the aDCT filter filled the gaps effectively. For the Jaszczak phantom, no secondary artifacts were induced after aDCT filtering. The percent mean square error and mean structure similarity of the aDCT filter were superior to those of the DCT2 filter at all noise levels. For the simulated striatal dopamine innervation study, the aDCT filter recovered the shape of the striatum and restored the striatum to reference activity ratios to the ideal value. Conclusions: The proposed aDCT filter can recover the missing gap data in the sinogram and improve the image quality and quantitative accuracy of PET images.
- Is Part Of:
- Medical physics. Volume 41:Issue 8(2014)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 8(2014)Part 1
- Issue Display:
- Volume 41, Issue 8, Part 1 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 8
- Part:
- 1
- Issue Sort Value:
- 2014-0041-0008-0001
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-11-30
- Subjects:
- Positron emission tomography (PET) -- Spatial resolution -- Image quality -- Integral transforms
discrete cosine transforms -- image resolution -- mean square error methods -- medical image processing -- phantoms -- positron emission tomography
positron emission tomography -- gap‐inpainting -- discrete cosine transform -- quantitative accuracy
Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Scintigraphy -- Measuring half‐life of a radioactive substance
Computed tomography -- Image reconstruction -- Positron emission tomography -- Image sensors -- Medical image noise -- Brain -- Medical image reconstruction -- Image analysis
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4886035 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27144.xml