Quality control procedures for dynamic treatment delivery techniques involving couch motion. Issue 8 (30th November 2016)
- Record Type:
- Journal Article
- Title:
- Quality control procedures for dynamic treatment delivery techniques involving couch motion. Issue 8 (30th November 2016)
- Main Title:
- Quality control procedures for dynamic treatment delivery techniques involving couch motion
- Authors:
- Yu, Victoria Y.
Fahimian, Benjamin P.
Xing, Lei
Hristov, Dimitre H. - Abstract:
- Abstract : In this study, the authors introduce and demonstrate quality control procedures for evaluating the geometric and dosimetric fidelity of dynamic treatment delivery techniques involving treatment couch motion synchronous with gantry and multileaf collimator (MLC). Tests were designed to evaluate positional accuracy, velocity constancy and accuracy for dynamic couch motion under a realistic weight load. A test evaluating the geometric accuracy of the system in delivering treatments over complex dynamic trajectories was also devised. Custom XML scripts that control the Varian TrueBeam™ STx (Serial #3) axes in Developer Mode were written to implement the delivery sequences for the tests. Delivered dose patterns were captured with radiographic film or the electronic portal imaging device. The couch translational accuracy in dynamic treatment mode was 0.01 cm. Rotational accuracy was within 0.3°, with 0.04 cm displacement of the rotational axis. Dose intensity profiles capturing the velocity constancy and accuracy for translations and rotation exhibited standard deviation and maximum deviations below 3%. For complex delivery involving MLC and couch motions, the overall translational accuracy for reproducing programmed patterns was within 0.06 cm. The authors conclude that in Developer Mode, TrueBeam™ is capable of delivering dynamic treatment delivery techniques involving couch motion with good geometric and dosimetric fidelity.
- Is Part Of:
- Medical physics. Volume 41:Issue 8(2014)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 8(2014)Part 1
- Issue Display:
- Volume 41, Issue 8, Part 1 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 8
- Part:
- 1
- Issue Sort Value:
- 2014-0041-0008-0001
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-11-30
- Subjects:
- radiation therapy equipment -- couch motion -- dynamic trajectory
Multileaf collimators -- Dosimetry -- Kinematics -- Quality assurance -- Linear accelerators -- Image guided radiation therapy -- Radiation treatment -- Collimators -- Radiography
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4886757 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 27144.xml