Technical Note: Correction for intra‐chamber dose gradients in reference dosimetry of flattening‐filter‐free MV photon beams. Issue 8 (21st July 2016)
- Record Type:
- Journal Article
- Title:
- Technical Note: Correction for intra‐chamber dose gradients in reference dosimetry of flattening‐filter‐free MV photon beams. Issue 8 (21st July 2016)
- Main Title:
- Technical Note: Correction for intra‐chamber dose gradients in reference dosimetry of flattening‐filter‐free MV photon beams
- Authors:
- Ruggieri, Ruggero
Naccarato, Stefania
Stavrev, Pavel
Stavreva, Nadejda
Pasetto, Stefano
Salamone, Ignazio
Alongi, Filippo - Abstract:
- Abstract : Purpose: To estimate and correct for the volume averaging effect which results from the intra‐chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening‐filter‐free (FFF) MV photon beams. Methods: An intra‐chamber dose gradients correction factor ( k icdg ) to the charge reading of a Farmer IC is estimated by comparison to a small volume IC (∼0.1 cm 3 ), in the FFF beams of a TrueBeam™ (Varian, Inc.) linear accelerators. An independent estimate of the correction for the volume averaging effect ( p vol ) is deduced using the ratio of the active length ( L ) of the Farmer IC to the integral of a high‐resolution FFF radial dose profile over this same length. Results: Mean (sd) values for k icdg equal to 1.0025 (0.0025) for 6 MV‐FFF, and equal to 1.0057 (0.0025) for 10 MV‐FFF, were estimated based on four dosimetry sessions, performed in a time interval of six months. Similarly, p vol Farmer equal to 1.0030 (0.0003) for 6 MV‐FFF, and equal to 1.0063 (0.0005) for 10 MV‐FFF, were computed. Conclusions: The systematic bias which results from intra‐chamber dose gradients when a Farmer IC is used for reference dosimetry in FFF MV photon beams is estimated to be −0.6% for 10 MV‐FFF, and −0.3% for 6 MV‐FFF, based on the obtained values of the factor k icdg . This bias can be corrected, within 0.1%, by the simple measure of p vol at the beginning of the dosimetry session.
- Is Part Of:
- Medical physics. Volume 43:Issue 8(2016)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 8(2016)Part 1
- Issue Display:
- Volume 43, Issue 8, Part 1 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 8
- Part:
- 1
- Issue Sort Value:
- 2016-0043-0008-0001
- Page Start:
- 4729
- Page End:
- 4733
- Publication Date:
- 2016-07-21
- Subjects:
- dosimetry -- ionisation chambers
Dose‐volume analysis
Scintigraphy
reference dosimetry -- Farmer ion‐chamber -- volume averaging -- flattening‐filter‐free
Dosimetry -- Photons -- Linear accelerators -- Integrated circuits -- Ion beams -- Hydrological cycles -- Error analysis -- Electric measurements -- Addendum -- Ionization chambers
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4958960 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1895.xml