A patch‐based pseudo‐CT approach for MRI‐only radiotherapy in the pelvis. Issue 8 (25th July 2016)
- Record Type:
- Journal Article
- Title:
- A patch‐based pseudo‐CT approach for MRI‐only radiotherapy in the pelvis. Issue 8 (25th July 2016)
- Main Title:
- A patch‐based pseudo‐CT approach for MRI‐only radiotherapy in the pelvis
- Authors:
- Andreasen, Daniel
Van Leemput, Koen
Edmund, Jens M. - Abstract:
- Abstract : Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so‐called pseudo‐computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch‐based method could produce accurate pCTs of the brain using conventional T 1 ‐weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co‐registered MRI/CT scan pairs and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch‐based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter‐patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water‐equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T 1 ‐weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave‐one‐out fashion and compared with the CT using frequently described metrics such as the voxel‐wiseAbstract : Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so‐called pseudo‐computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch‐based method could produce accurate pCTs of the brain using conventional T 1 ‐weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co‐registered MRI/CT scan pairs and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch‐based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter‐patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water‐equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T 1 ‐weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave‐one‐out fashion and compared with the CT using frequently described metrics such as the voxel‐wise mean absolute error (MAEvox ) and the deviation in water‐equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose–volume histogram (DVH) point deviations and γ ‐index analysis. Results: The patch‐based approach had an average MAEvox of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ ‐index pass rate of 0.97 using a 1%/1 mm criterion. The patch‐based approach showed a significantly better performance than the baseline water pCT in almost all metrics. The approximate patch search strategy was 70x faster than a brute‐force search, with an average prediction time of 20.8 min. Conclusions: The authors showed that a patch‐based method based on affine registrations and T 1 ‐weighted MRI could generate accurate pCTs of the pelvis. The main source of differences between pCT and CT was positional changes of air pockets and body outline. … (more)
- Is Part Of:
- Medical physics. Volume 43:Issue 8(2016)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 8(2016)Part 1
- Issue Display:
- Volume 43, Issue 8, Part 1 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 8
- Part:
- 1
- Issue Sort Value:
- 2016-0043-0008-0001
- Page Start:
- 4742
- Page End:
- 4752
- Publication Date:
- 2016-07-25
- Subjects:
- biomedical MRI -- brain -- computerised tomography -- dosimetry -- image registration -- medical image processing -- radiation therapy
Computed tomography -- Registration -- Dose‐volume analysis -- MRI: anatomic, functional, spectral, diffusion -- Magnetic resonance imaging
Involving electronic [emr] or nuclear [nmr] magnetic resonance, e.g. magnetic resonance imaging -- Computerised tomographs -- Radiation therapy -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Scintigraphy
radiotherapy -- MRI‐only -- pseudo‐CT -- patch -- pelvis
Magnetic resonance imaging -- Computed tomography -- Dosimetry -- Brain -- Tissues -- Databases -- Medical treatment planning -- Medical imaging
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4958676 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1895.xml