Barrett, Tristan - Abstract:
- Highlights: Rectal distension had a significant negative effect on the quality of DWI. There was a correlation between rectal distension and T2W motion artefact. Rectal distension had no significant effect on T2 sharpness and DCE image quality. Targeted biopsy PPV was higher for mild versus moderate/severe rectal distension. Bowel preparation prior to prostate MRI is advised to improve image quality. Abstract: Purpose: To evaluate the effect of rectal distension on the quality of anatomical and functional prostate multiparametric (mp) MRI. Materials and methods: Multiparametric (mp) 3T-MRI images of 173 patients were independently evaluated by two radiologists in this retrospective study. Planimetry rectal volumes were derived and a subjective assessment of rectal distension was made using a 5-point Likert scale (1 = no stool/gas, 5 = large amount of stool/gas). Image quality of diffusion-weighted imaging (DWI) was evaluated using a 5-point Likert scale. DWI was further scored for distortion and artefact. T2W images were evaluated for image sharpness and the presence of motion artefact. The stability of the dynamic contrast-enhancement acquisition was assessed by recording the number of corrupt data points during the wash-out phase. Results: There was a strong correlation between subjective scoring of rectal loading and objectively measured rectal volume (r = 0.82), p < 0.001. A significant correlation was shown between increased rectal distension and both reduced DW imageHighlights: Rectal distension had a significant negative effect on the quality of DWI. There was a correlation between rectal distension and T2W motion artefact. Rectal distension had no significant effect on T2 sharpness and DCE image quality. Targeted biopsy PPV was higher for mild versus moderate/severe rectal distension. Bowel preparation prior to prostate MRI is advised to improve image quality. Abstract: Purpose: To evaluate the effect of rectal distension on the quality of anatomical and functional prostate multiparametric (mp) MRI. Materials and methods: Multiparametric (mp) 3T-MRI images of 173 patients were independently evaluated by two radiologists in this retrospective study. Planimetry rectal volumes were derived and a subjective assessment of rectal distension was made using a 5-point Likert scale (1 = no stool/gas, 5 = large amount of stool/gas). Image quality of diffusion-weighted imaging (DWI) was evaluated using a 5-point Likert scale. DWI was further scored for distortion and artefact. T2W images were evaluated for image sharpness and the presence of motion artefact. The stability of the dynamic contrast-enhancement acquisition was assessed by recording the number of corrupt data points during the wash-out phase. Results: There was a strong correlation between subjective scoring of rectal loading and objectively measured rectal volume (r = 0.82), p < 0.001. A significant correlation was shown between increased rectal distension and both reduced DW image quality (r = −0.628, p < 0.001), and increased DW image distortion (r = 0.814, p < 0.001). There was also a significant trend for rectal distension to increase artefact at DWI (r = 0.154, p = 0.042). Increased rectal distension led to increased motion artefact on T2 (p = 0.0096), but did not have a significant effect on T2-sharpness (p = 0.0638). There was no relationship between rectal distension and DCE image quality (p = 0.693). 63 patients underwent lesion-targeted biopsy post MRI, there was a trend to higher positive predictive values in patients with minor rectal distension (34/38, 89.5%) compared to those with moderate/marked distension (18/25, 72%), p = 0.09. Conclusion: Rectal distension has a significant negative effect on the quality of both T2W and DW images. Consideration should therefore be given to bowel preparation prior to prostate mpMRI to optimise image quality. … (more)
- Is Part Of:
- European journal of radiology. Issue 90(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 90(2017)
- Issue Display:
- Volume 90, Issue 90 (2017)
- Year:
- 2017
- Volume:
- 90
- Issue:
- 90
- Issue Sort Value:
- 2017-0090-0090-0000
- Page Start:
- 174
- Page End:
- 180
- Publication Date:
- 2017-05
- Subjects:
- Rectal distension -- Multiparametric MRI -- Prostate -- Image quality -- Susceptibility artefact
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2017.02.029 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 792.xml