Detection of testosterone esters in blood. Issue 11 (21st December 2015)
- Record Type:
- Journal Article
- Title:
- Detection of testosterone esters in blood. Issue 11 (21st December 2015)
- Main Title:
- Detection of testosterone esters in blood
- Authors:
- Forsdahl, Guro
Erceg, Damir
Geisendorfer, Thomas
Turkalj, Mirjana
Plavec, Davor
Thevis, Mario
Tretzel, Laura
Gmeiner, Günter - Abstract:
- Abstract : Injections of synthetic esters of testosterone are among the most common forms of testosterone application. In doping control, the detection of an intact ester of testosterone in blood gives unequivocal proof of the administration of exogenous testosterone. The aim of the current project was to investigate the detection window for injected testosterone esters as a mixed substance preparation and as a single substance preparation in serum and plasma. Furthermore, the suitability of different types of blood collection devices was evaluated. Collection tubes with stabilizing additives, as well as non‐stabilized serum separation tubes, were tested. A clinical study with six participants was carried out, comprising a single intramuscular injection of either 1000 mg testosterone undecanoate (Nebido ® ) or a mixture of 30 mg testosterone propionate, 60 mg testosterone phenylpropionate, 60 mg testosterone isocaproate, and 100 mg testosterone decanoate (Sustanon ® ). Blood was collected throughout a testing period of 60 days. The applied analytical method for blood analysis included liquid‐liquid extraction and preparation of oxime derivatives, prior to TLX‐sample clean‐up and liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) detection. All investigated testosterone esters could be detected in post‐administration blood samples. The detection time depended on the type of ester administered. Furthermore, results from the study show that measured blood concentrationsAbstract : Injections of synthetic esters of testosterone are among the most common forms of testosterone application. In doping control, the detection of an intact ester of testosterone in blood gives unequivocal proof of the administration of exogenous testosterone. The aim of the current project was to investigate the detection window for injected testosterone esters as a mixed substance preparation and as a single substance preparation in serum and plasma. Furthermore, the suitability of different types of blood collection devices was evaluated. Collection tubes with stabilizing additives, as well as non‐stabilized serum separation tubes, were tested. A clinical study with six participants was carried out, comprising a single intramuscular injection of either 1000 mg testosterone undecanoate (Nebido ® ) or a mixture of 30 mg testosterone propionate, 60 mg testosterone phenylpropionate, 60 mg testosterone isocaproate, and 100 mg testosterone decanoate (Sustanon ® ). Blood was collected throughout a testing period of 60 days. The applied analytical method for blood analysis included liquid‐liquid extraction and preparation of oxime derivatives, prior to TLX‐sample clean‐up and liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) detection. All investigated testosterone esters could be detected in post‐administration blood samples. The detection time depended on the type of ester administered. Furthermore, results from the study show that measured blood concentrations of especially short‐chained testosterone esters are influenced by the type of blood collection device applied. The testosterone ester detection window, however, was comparable. Copyright © 2015 John Wiley & Sons, Ltd. Abstract : The direct detection of an intact testosterone ester leads to unequivocal proof of doping with testosterone. In a clinical study, the detection times of various testosterone esters in blood were investigated, subsequent to single intramuscular injections. … (more)
- Is Part Of:
- Drug testing and analysis. Volume 7:Issue 11/12(2015:Nov.)
- Journal:
- Drug testing and analysis
- Issue:
- Volume 7:Issue 11/12(2015:Nov.)
- Issue Display:
- Volume 7, Issue 11/12 (2015)
- Year:
- 2015
- Volume:
- 7
- Issue:
- 11/12
- Issue Sort Value:
- 2015-0007-NaN-0000
- Page Start:
- 983
- Page End:
- 989
- Publication Date:
- 2015-12-21
- Subjects:
- doping -- testosterone ester -- blood -- detection time -- LC‐MS/MS
Drugs -- Analysis -- Periodicals
Drug testing -- Periodicals
Chemistry, Forensic -- Periodicals
615.1901 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611 ↗
http://rzblx1.uni-regensburg.de/ezeit/warpto.phtml?colors=7&jour_id=110501 ↗
http://www3.interscience.wiley.com/journal/121408477/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dta.1914 ↗
- Languages:
- English
- ISSNs:
- 1942-7603
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3629.424000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 460.xml