Verifying tumor position during stereotactic body radiation therapy delivery using (limited-arc) cone beam computed tomography imaging. Issue 3 (June 2017)
- Record Type:
- Journal Article
- Title:
- Verifying tumor position during stereotactic body radiation therapy delivery using (limited-arc) cone beam computed tomography imaging. Issue 3 (June 2017)
- Main Title:
- Verifying tumor position during stereotactic body radiation therapy delivery using (limited-arc) cone beam computed tomography imaging
- Authors:
- Hazelaar, Colien
Dahele, Max
Scheib, Stefan
Slotman, Ben J.
Verbakel, Wilko F.A.R. - Abstract:
- Abstract: Background and purpose: Proof of tumor position during stereotactic body radiotherapy (SBRT) delivery is desirable. We investigated if cone-beam CT (CBCT) scans reconstructed from (collimated) fluoroscopic kV images acquired during irradiation could show the dominant tumor position. Materials and methods: Full-arc CBCT scans were reconstructed using FDK filtered back projection from 38 kV fluoroscopy datasets (16 patients) continuously acquired during volumetric modulated spine SBRT. CBCT-CT match values were compared to the average spine offset values found using template matching + triangulation of the individual kV images. Multiple limited-arc CBCTs were reconstructed from fluoroscopic images acquired during lung SBRT of an anthropomorphic thorax phantom using 20–180° arc lengths and for 3 breath-hold lung SBRT patients. Results: Differences between 3D CBCT-CT match results and average spine offsets found using template matching + triangulation were 0.1 ± 0.1 mm for all directions (range: 0.0–0.5 mm). For limited-arc CBCTs of the thorax phantom, the automatic 3D CBCT-CT match results for arc lengths of 80–180° were ≤1 mm. 20° CBCT reconstruction still allowed for positional verification in 2D. Conclusions: (Limited-arc) CBCT reconstructions of kV images acquired during irradiation can identify the dominant position of the tumor during treatment delivery.
- Is Part Of:
- Radiotherapy and oncology. Volume 123:Issue 3(2017:Jun.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 123:Issue 3(2017:Jun.)
- Issue Display:
- Volume 123, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 123
- Issue:
- 3
- Issue Sort Value:
- 2017-0123-0003-0000
- Page Start:
- 355
- Page End:
- 362
- Publication Date:
- 2017-06
- Subjects:
- Cone beam computed tomography -- Fluoroscopy -- Stereotactic body radiation therapy -- Intrafraction monitoring -- Positional verification
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2017.04.022 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1926.xml