Air density dependence of the response of the PTW SourceCheck 4pi ionization chamber for 125I brachytherapy seeds. (June 2017)
- Record Type:
- Journal Article
- Title:
- Air density dependence of the response of the PTW SourceCheck 4pi ionization chamber for 125I brachytherapy seeds. (June 2017)
- Main Title:
- Air density dependence of the response of the PTW SourceCheck 4pi ionization chamber for 125I brachytherapy seeds
- Authors:
- Torres del Río, J.
Tornero-López, A.M.
Guirado, D.
Pérez-Calatayud, J.
Lallena, A.M. - Abstract:
- Highlights: Air density dependence of the response of the SourceCheck 4pi ionization chamber. Comparison with responses of HDR 1000 Plus and old SourceCheck ionization chambers. Verification of the linear dependence of the residual response on air density. Abstract: Purpose: To analyze the air density dependence of the response of the new SourceCheck 4pi ionization chamber, manufactured by PTW. Methods: The air density dependence of three different SourceCheck 4pi chambers was studied by measuring 125 I sources. Measurements were taken by varying the pressure from 746.6 to 986.6 hPa in a pressure chamber. Three different HDR 1000 Plus ionization chambers were also analyzed under similar conditions. A linear and a potential-like function of the air density were fitted to experimental data and their achievement in describing them was analyzed. Results: SourceCheck 4pi chamber response showed a residual dependence on the air density once the standard pressure and temperature factor was applied. The chamber response was overestimated when the air density was below that under normal atmospheric conditions. A similar dependence was found for the HDR 1000 Plus chambers analyzed. A linear function of the air density permitted a very good description of this residual dependence, better than with a potential function. No significant variability between the different specimens of the same chamber model studied was found. Conclusion: The effect of overestimation observed in the chamberHighlights: Air density dependence of the response of the SourceCheck 4pi ionization chamber. Comparison with responses of HDR 1000 Plus and old SourceCheck ionization chambers. Verification of the linear dependence of the residual response on air density. Abstract: Purpose: To analyze the air density dependence of the response of the new SourceCheck 4pi ionization chamber, manufactured by PTW. Methods: The air density dependence of three different SourceCheck 4pi chambers was studied by measuring 125 I sources. Measurements were taken by varying the pressure from 746.6 to 986.6 hPa in a pressure chamber. Three different HDR 1000 Plus ionization chambers were also analyzed under similar conditions. A linear and a potential-like function of the air density were fitted to experimental data and their achievement in describing them was analyzed. Results: SourceCheck 4pi chamber response showed a residual dependence on the air density once the standard pressure and temperature factor was applied. The chamber response was overestimated when the air density was below that under normal atmospheric conditions. A similar dependence was found for the HDR 1000 Plus chambers analyzed. A linear function of the air density permitted a very good description of this residual dependence, better than with a potential function. No significant variability between the different specimens of the same chamber model studied was found. Conclusion: The effect of overestimation observed in the chamber responses once they are corrected for the standard pressure and temperature may represent a non-negligible ∼ 4 % overestimation in high altitude cities as ours (700 m AMSL). This overestimation behaves linearly with the air density in all cases analyzed. … (more)
- Is Part Of:
- Physica medica. Volume 38(2017)
- Journal:
- Physica medica
- Issue:
- Volume 38(2017)
- Issue Display:
- Volume 38, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 38
- Issue:
- 2017
- Issue Sort Value:
- 2017-0038-2017-0000
- Page Start:
- 93
- Page End:
- 97
- Publication Date:
- 2017-06
- Subjects:
- Brachytherapy -- Low-energy sources -- Ionization chamber -- Air density dependence -- PTW SourceCheck 4pi
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.05.056 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1776.xml