Assessment of cardiac allograft systolic function by global longitudinal strain: From donor to recipient. Issue 5 (8th April 2017)
- Record Type:
- Journal Article
- Title:
- Assessment of cardiac allograft systolic function by global longitudinal strain: From donor to recipient. Issue 5 (8th April 2017)
- Main Title:
- Assessment of cardiac allograft systolic function by global longitudinal strain: From donor to recipient
- Authors:
- DeVore, Adam D.
Alenezi, Fawaz
Krishnamoorthy, Arun
Ersboll, Mads
Samsky, Marc D.
Schulte, Phillip J.
Patel, Chetan B.
Rogers, Joseph G.
Milano, Carmelo A.
Velazquez, Eric J.
Khouri, Michel G. - Abstract:
- Abstract: Background: Cardiac allografts are routinely evaluated by left ventricular ejection fraction (LVEF) before and after transplantation. However, myocardial deformation analyses with LV global longitudinal strain (GLS) are more sensitive for detecting impaired LV myocardial systolic performance compared with LVEF. Methods: We analyzed echocardiograms in 34 heart donor‐recipient pairs transplanted at Duke University from 2000 to 2013. Assessments of allograft LV systolic function by LVEF and/or LV GLS were performed on echocardiograms obtained pre‐explanation in donors and serially in corresponding recipients. Results: Donors had a median LVEF of 55% (25th, 75th percentile, 54% to 60%). Median donor LV GLS was −14.6% (−13.7 to −17.3%); LV GLS was abnormal (ie, >−16%) in 68% of donors. Post‐transplantation, LV GLS was further impaired at 6 weeks (median ‐11.8%; −11.0 to −13.4%) and 3 months (median −11.4%; −10.3 to −13.9%) before recovering to pretransplant levels in follow‐up. Median LVEF remained ≥50% throughout follow‐up. We found no association between donor LV GLS and post‐transplant outcomes, including all‐cause hospitalization and mortality. Conclusions: GLS demonstrates allograft LV systolic dysfunction in donors and recipients not detected by LVEF. The clinical implications of subclinical allograft dysfunction detected by LV GLS require further study.
- Is Part Of:
- Clinical transplantation. Volume 31:Issue 5(2017)
- Journal:
- Clinical transplantation
- Issue:
- Volume 31:Issue 5(2017)
- Issue Display:
- Volume 31, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 5
- Issue Sort Value:
- 2017-0031-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-04-08
- Subjects:
- donor selection -- echocardiography -- heart transplant -- left ventricular function -- strain
Transplantation of organs, tissues, etc -- Periodicals
617.95 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=ctr ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ctr.12961 ↗
- Languages:
- English
- ISSNs:
- 0902-0063
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.399780
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 712.xml