Naudy, S. - Abstract:
- Abstract : Introduction: During a treatment of lung lesion in stereotactic condition, for greater reproducibility, patients are immobilized with a complex and customized contention. The objective of this study is to determine the dosimetric impact of contention used in CGFL with the treatment couch. Materials and methods: Pulmonary stereotactic contentions used at CGFL are customizable vacuum cushions (BlueBAG™ BodyFIX). Ten treatment plans was performed without contention and couch. Each uses an arrangement of non modulated beams of 6 MV. Dose distributions of the resulting plans were re-calculated with the obtained Monitor Units, but with including of BlueBAG and treatment couch ("Exact IGRT" of Varian). Hounsfield Units used for internal structure couch are −945 and −300 for external structure. All dose distributions were calculated with Acuros XB V.11 (Varian Medical System). Results: New dose calculation with treatment couch and contention indicate a deterioration of around 1.9% of the D98% . Note that in 9 of the 10 case of the study, this D98% remains above the prescribe dose. The volume PTV receiving a dose is reduced by 1.6%. The most significant degradation was observed on the D50% and is 2.5% on average. Conclusions: Dosimetric impact of treatment couch modelling and contention in pulmonary stereotactic treatment is moderate. Although a significant deterioration of the dosimetric index was observed, coverage of prescribed dose remains acceptable.
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 4
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 4
- Issue Display:
- Volume 32, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 4
- Issue Sort Value:
- 2016-0032-0004-0000
- Page Start:
- 382
- Page End:
- Publication Date:
- 2016-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.11.048 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 29.xml