26. Evaluation of the EpiDream method for quality assurance (QA) of electron beams using a Varian electronic portal imaging device (EPID). (December 2016)
- Record Type:
- Journal Article
- Title:
- 26. Evaluation of the EpiDream method for quality assurance (QA) of electron beams using a Varian electronic portal imaging device (EPID). (December 2016)
- Main Title:
- 26. Evaluation of the EpiDream method for quality assurance (QA) of electron beams using a Varian electronic portal imaging device (EPID)
- Authors:
- Sors, A.
Dudouet, P.
Franck, D.
Boutry, C. - Abstract:
- Abstract : Introduction: The aim of the study is to evaluate the use of EPID for electron beams QA defined by the 07/27/2007 French decision with a new approach in absorbed dose to water reconstruction: the EpiDream method. Methods: The study was performed on two Varian LINACs, equipped with EPID (either with the AS500 or AS1000) for electron beams of 6, 9, 12, 15 and 18 MeV. Each EPID was calibrated with EpiDream application in order to obtain from the Grey Level (GL) image a dose matrix computed in water at the reference depth(zref) of the energy studied. For each energy, GL integrated images were corrected of dark field and acquired using AM Maintenance system(Varian) at the detector source distance (DSD) = 100 cm and DSD = (100 + zref) cm for different parameters : field sizes(6 × 6–20 × 20 cm 2, delivered MU (3-300 MU), dose rate(100–300 MU/min). For each irradiation condition, a gamma index evaluation was performed between dose matrix computed by Eclipse TPS algorithm (eMC v13.6, Varian) and dose matrix computed by EpiDream method (DM EpiDream). For a 15 × 15 cm 2 field size, a comparison was performed between radial and transverse dose profiles measured with a 0.125 cm 3 ionization chamber(PTW31010) in water at zref for SSD = 100 cm and dose profiles obtained from DM EpiDream, considering: homogeneity and symmetry parameters, penumbra and correlation coefficient. Results: Data analysis is in progress. However, first results are encouraging: At 9 MeV and for aAbstract : Introduction: The aim of the study is to evaluate the use of EPID for electron beams QA defined by the 07/27/2007 French decision with a new approach in absorbed dose to water reconstruction: the EpiDream method. Methods: The study was performed on two Varian LINACs, equipped with EPID (either with the AS500 or AS1000) for electron beams of 6, 9, 12, 15 and 18 MeV. Each EPID was calibrated with EpiDream application in order to obtain from the Grey Level (GL) image a dose matrix computed in water at the reference depth(zref) of the energy studied. For each energy, GL integrated images were corrected of dark field and acquired using AM Maintenance system(Varian) at the detector source distance (DSD) = 100 cm and DSD = (100 + zref) cm for different parameters : field sizes(6 × 6–20 × 20 cm 2, delivered MU (3-300 MU), dose rate(100–300 MU/min). For each irradiation condition, a gamma index evaluation was performed between dose matrix computed by Eclipse TPS algorithm (eMC v13.6, Varian) and dose matrix computed by EpiDream method (DM EpiDream). For a 15 × 15 cm 2 field size, a comparison was performed between radial and transverse dose profiles measured with a 0.125 cm 3 ionization chamber(PTW31010) in water at zref for SSD = 100 cm and dose profiles obtained from DM EpiDream, considering: homogeneity and symmetry parameters, penumbra and correlation coefficient. Results: Data analysis is in progress. However, first results are encouraging: At 9 MeV and for a DSD = 100 + zref, the mean gamma index value for 6 × 6, 10 × 10, and 15 × 15 cm 2 field sizes is respectively: 99.9% ( σ = 0.1%), 99.8% ( σ = 0.32%), 96.3% ( σ = 2.2%). Conclusions: The EpidDream method would permit to perform electrons beams QA using EPID for all gantry angles by maximizing measurement reproducibility. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 4
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 4
- Issue Display:
- Volume 32, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 4
- Issue Sort Value:
- 2016-0032-0004-0000
- Page Start:
- 353
- Page End:
- Publication Date:
- 2016-12
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.11.078 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 29.xml