Torsional power study using CENTURION phacoemulsification technology. (22nd April 2016)
- Record Type:
- Journal Article
- Title:
- Torsional power study using CENTURION phacoemulsification technology. (22nd April 2016)
- Main Title:
- Torsional power study using CENTURION phacoemulsification technology
- Authors:
- Jensen, Jason D
Shi, Dallas S
Robinson, Mark S
Kramer, Gregory D
Zaugg, Brian
Stagg, Brian C
Pettey, Jeff H
Barlow, William R
Olson, Randall J - Abstract:
- Abstract: Background: To evaluate the effect of varying levels of power on phacoemulsification efficiency using the CENTURION Vision System. Methods: Formalin‐soaked porcine lenses were divided into 2‐mm cubes; 0.9‐mm, balanced tips were used. Torsional power levels were tested from 10% to 100% at 10% intervals. Vacuum was set to 550 mmHg, aspiration to 50 ml/min, and intraocular pressure at 50 mmHg. Efficiency (time to lens removal) and chatter (number of lens fragment repulsions from the tip) were determined. Results: Increasing torsional power up to 60% increased efficiency. This effect was linear from 30 to 60% power ( R 2 = .90; P < 0.05). There were no significant differences in efficiency past 60%. Chatter was highest at 10% power and decreased linearly ( R 2 = .87; P = 0.007) as power was increased up to 60% power, and chatter did not improve above this power level. Conclusions: Power improved efficiency only up to a 60% power level, and then was negligible. Chatter correlated well with power up to the 60% level, so that as power was increased, chatter decreased. Because there are no additional benefits in efficiency past 60% power, and because chatter is minimal at 60% power, we recommend torsional ultrasound at 60% as the optimal power setting for using the CENTURION System for phacoemulsification.l
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 44:Number 8(2016)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 44:Number 8(2016)
- Issue Display:
- Volume 44, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 8
- Issue Sort Value:
- 2016-0044-0008-0000
- Page Start:
- 710
- Page End:
- 713
- Publication Date:
- 2016-04-22
- Subjects:
- animal -- cataract -- cataract extraction -- crystalline -- lens -- mechanical -- models -- torsion
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.12748 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1106.xml