Incident air kerma to absorbed organ dose conversion factors for breast and lung in PA thorax radiography: The effect of patient thickness and radiation quality. Issue 12 (December 2016)
- Record Type:
- Journal Article
- Title:
- Incident air kerma to absorbed organ dose conversion factors for breast and lung in PA thorax radiography: The effect of patient thickness and radiation quality. Issue 12 (December 2016)
- Main Title:
- Incident air kerma to absorbed organ dose conversion factors for breast and lung in PA thorax radiography: The effect of patient thickness and radiation quality
- Authors:
- Kelaranta, A.
Toroi, P.
Vock, P. - Abstract:
- Graphical abstract: Highlights: Radiation quality and patient thickness affect the organ dose conversion factors. Thickness-specific and radiation quality-specific conversion factors are needed. Monte Carlo methods were used to determine the organ dose conversion factors. Abstract: Purpose: Converting the measurable quantities to patient organ doses in projection radiography is usually based on a standard-sized patient model and a specific radiation quality, which are likely to differ from the real situation. Large inaccuracies can therefore be obtained in organ doses, because organ doses are dependent on the exposure parameters, exposure geometry and patient anatomy. In this study, the effect of radiation quality and patient thickness on the organ dose conversion factors were determined. Methods: In this study, the posterior–anterior projection radiograph of the thorax was selected in order to determine the effect of radiation quality (tube voltages of 70–130 kV and total filtrations of 3 mmAl to 4 mmAl + 0.2 mmCu) and patient thickness (anterior–posterior thicknesses of 19.4–30.8 cm) on the breast and lung dose conversion factors. For this purpose, Monte Carlo simulation programs ImpactMC and PCXMC were used with computed tomography examination data of adult male and female patients and mathematical hermaphrodite phantoms, respectively. Results: Compared to the reference beam quality and patient thickness, the relative variation range in organ dose conversion factors wasGraphical abstract: Highlights: Radiation quality and patient thickness affect the organ dose conversion factors. Thickness-specific and radiation quality-specific conversion factors are needed. Monte Carlo methods were used to determine the organ dose conversion factors. Abstract: Purpose: Converting the measurable quantities to patient organ doses in projection radiography is usually based on a standard-sized patient model and a specific radiation quality, which are likely to differ from the real situation. Large inaccuracies can therefore be obtained in organ doses, because organ doses are dependent on the exposure parameters, exposure geometry and patient anatomy. In this study, the effect of radiation quality and patient thickness on the organ dose conversion factors were determined. Methods: In this study, the posterior–anterior projection radiograph of the thorax was selected in order to determine the effect of radiation quality (tube voltages of 70–130 kV and total filtrations of 3 mmAl to 4 mmAl + 0.2 mmCu) and patient thickness (anterior–posterior thicknesses of 19.4–30.8 cm) on the breast and lung dose conversion factors. For this purpose, Monte Carlo simulation programs ImpactMC and PCXMC were used with computed tomography examination data of adult male and female patients and mathematical hermaphrodite phantoms, respectively. Results: Compared to the reference beam quality and patient thickness, the relative variation range in organ dose conversion factors was up to 74% for different radiation qualities and 122% for different patient thicknesses. Conclusions: Conversion factors should only be used with comprehensive understanding of the exposure conditions, considering the exposure parameters, exposure geometry and patient anatomy they are valid for. This study demonstrates that patient thickness-specific and radiation quality-specific conversion factors are needed in projection radiography. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 12(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 12(2016)
- Issue Display:
- Volume 32, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 12
- Issue Sort Value:
- 2016-0032-0012-0000
- Page Start:
- 1594
- Page End:
- 1601
- Publication Date:
- 2016-12
- Subjects:
- Organ dose -- Conversion factor -- Thorax X-ray examination -- Radiation quality -- Patient thickness
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.11.113 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1787.xml