Quantitative Ultrasound Comparison of MAT and 4T1 Mammary Tumors in Mice and Rats Across Multiple Imaging Systems. (1st August 2015)
- Record Type:
- Journal Article
- Title:
- Quantitative Ultrasound Comparison of MAT and 4T1 Mammary Tumors in Mice and Rats Across Multiple Imaging Systems. (1st August 2015)
- Main Title:
- Quantitative Ultrasound Comparison of MAT and 4T1 Mammary Tumors in Mice and Rats Across Multiple Imaging Systems
- Authors:
- Wirtzfeld, Lauren A.
Ghoshal, Goutam
Rosado-Mendez, Ivan M.
Nam, Kibo
Park, Yeonjoo
Pawlicki, Alexander D.
Miller, Rita J.
Simpson, Douglas G.
Zagzebski, James A.
Oelze, Michael L.
Hall, Timothy J.
O'Brien, William D. - Abstract:
- Abstract : Objectives: Quantitative ultrasound estimates such as the frequency‐dependent backscatter coefficient (BSC) have the potential to enhance noninvasive tissue characterization and to identify tumors better than traditional B‐mode imaging. Thus, investigating system independence of BSC estimates from multiple imaging platforms is important for assessing their capabilities to detect tissue differences. Methods: Mouse and rat mammary tumor models, 4T1 and MAT, respectively, were used in a comparative experiment using 3 imaging systems (Siemens, Ultrasonix, and VisualSonics) with 5 different transducers covering a range of ultrasonic frequencies. Results: Functional analysis of variance of the MAT and 4T1 BSC‐versus‐frequency curves revealed statistically significant differences between the two tumor types. Variations also were found among results from different transducers, attributable to frequency range effects. At 3 to 8 MHz, tumor BSC functions using different systems showed no differences between tumor type, but at 10 to 20 MHz, there were differences between 4T1 and MAT tumors. Fitting an average spline model to the combined BSC estimates (3–22 MHz) demonstrated that the BSC differences between tumors increased with increasing frequency, with the greatest separation above 15 MHz. Confining the analysis to larger tumors resulted in better discrimination over a wider bandwidth. Conclusions: Confining the comparison to higher ultrasonic frequencies or larger tumorAbstract : Objectives: Quantitative ultrasound estimates such as the frequency‐dependent backscatter coefficient (BSC) have the potential to enhance noninvasive tissue characterization and to identify tumors better than traditional B‐mode imaging. Thus, investigating system independence of BSC estimates from multiple imaging platforms is important for assessing their capabilities to detect tissue differences. Methods: Mouse and rat mammary tumor models, 4T1 and MAT, respectively, were used in a comparative experiment using 3 imaging systems (Siemens, Ultrasonix, and VisualSonics) with 5 different transducers covering a range of ultrasonic frequencies. Results: Functional analysis of variance of the MAT and 4T1 BSC‐versus‐frequency curves revealed statistically significant differences between the two tumor types. Variations also were found among results from different transducers, attributable to frequency range effects. At 3 to 8 MHz, tumor BSC functions using different systems showed no differences between tumor type, but at 10 to 20 MHz, there were differences between 4T1 and MAT tumors. Fitting an average spline model to the combined BSC estimates (3–22 MHz) demonstrated that the BSC differences between tumors increased with increasing frequency, with the greatest separation above 15 MHz. Confining the analysis to larger tumors resulted in better discrimination over a wider bandwidth. Conclusions: Confining the comparison to higher ultrasonic frequencies or larger tumor sizes allowed for separation of BSC‐versus‐frequency curves from 4T1 and MAT tumors. These constraints ensure that a greater fraction of the backscattered signals originated from within the tumor, thus demonstrating that statistically significant tumor differences were detected. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 34:Number 8(2015)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 34:Number 8(2015)
- Issue Display:
- Volume 34, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 34
- Issue:
- 8
- Issue Sort Value:
- 2015-0034-0008-0000
- Page Start:
- 1373
- Page End:
- 1383
- Publication Date:
- 2015-08-01
- Subjects:
- backscatter coefficient -- mammary tumor models -- quantitative ultrasound
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.7863/ultra.34.8.1373 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1327.xml