Effect of B‐Mode Optimization Techniques on Fetal Bowel Echogenicity Using Computerized Image Analysis. (1st September 2013)
- Record Type:
- Journal Article
- Title:
- Effect of B‐Mode Optimization Techniques on Fetal Bowel Echogenicity Using Computerized Image Analysis. (1st September 2013)
- Main Title:
- Effect of B‐Mode Optimization Techniques on Fetal Bowel Echogenicity Using Computerized Image Analysis
- Authors:
- Karayanni-Ammuri, Rasha
Ohel, Gonen
Degani, Shimon
Zreik, Amer
Odeh, Marwan
Shapiro, Israel
Leibovitz, Zvi - Abstract:
- Abstract : Objectives: The purpose of this study was to provide and compare measurable parameters for normal fetal bowel echogenicity under predefined B‐mode scanning presets. Methods: Forty healthy fetuses underwent 14‐ to 17‐week ultrasound scans, and 40 underwent 21‐ to 25‐week scans. Sagittal, coronal, and axial fetal abdominal images were tested using predefined B‐mode presets. The presets differed from fundamental imaging by isolated activation of harmonic imaging, compound resolution imaging, speckle reduction imaging, focus and frequency composite imaging, and coded excitation imaging features. A transabdominal probe was used in all fetuses, and transvaginal images were added for the 14‐ to 17‐week scans. The images were studied with custom‐developed software, which provided a grayscale analysis of the pixels in the region of interest within the image. The mean brightness of the pixels from the fetal bowel area was calculated. Results: The 14‐ to 17‐week transabdominal scans showed significantly higher mean brightness on harmonic imaging compared to fundamental imaging ( P < .01). Activation of coded excitation and compound resolution imaging in these scans resulted in a significant decrease in the mean brightness compared to fundamental imaging. Mean bowel brightness values on the 21‐ to 25‐week transabdominal scans did not differ significantly with the use of the different imaging presets compared to fundamental imaging. Conclusions: Transabdominal harmonic imagingAbstract : Objectives: The purpose of this study was to provide and compare measurable parameters for normal fetal bowel echogenicity under predefined B‐mode scanning presets. Methods: Forty healthy fetuses underwent 14‐ to 17‐week ultrasound scans, and 40 underwent 21‐ to 25‐week scans. Sagittal, coronal, and axial fetal abdominal images were tested using predefined B‐mode presets. The presets differed from fundamental imaging by isolated activation of harmonic imaging, compound resolution imaging, speckle reduction imaging, focus and frequency composite imaging, and coded excitation imaging features. A transabdominal probe was used in all fetuses, and transvaginal images were added for the 14‐ to 17‐week scans. The images were studied with custom‐developed software, which provided a grayscale analysis of the pixels in the region of interest within the image. The mean brightness of the pixels from the fetal bowel area was calculated. Results: The 14‐ to 17‐week transabdominal scans showed significantly higher mean brightness on harmonic imaging compared to fundamental imaging ( P < .01). Activation of coded excitation and compound resolution imaging in these scans resulted in a significant decrease in the mean brightness compared to fundamental imaging. Mean bowel brightness values on the 21‐ to 25‐week transabdominal scans did not differ significantly with the use of the different imaging presets compared to fundamental imaging. Conclusions: Transabdominal harmonic imaging in the early second trimester may significantly increase the mean brightness of the fetal bowel tissue. Contrarily, compound resolution imaging and coded excitation imaging produce the opposite effect on bowel echogenicity. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 32:Number 9(2013)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 32:Number 9(2013)
- Issue Display:
- Volume 32, Issue 9 (2013)
- Year:
- 2013
- Volume:
- 32
- Issue:
- 9
- Issue Sort Value:
- 2013-0032-0009-0000
- Page Start:
- 1615
- Page End:
- 1621
- Publication Date:
- 2013-09-01
- Subjects:
- B-mode optimization -- fetal bowel echogenicity -- imaging preset
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.7863/ultra.32.9.1615 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2251.xml