Spotnitz, Henry M. - Abstract:
- Abstract : Objectives: Biventricular pacing may ameliorate symptoms of acute heart failure. Speckle‐tracking echocardiography can assess cardiac function to elucidate mechanisms of benefit. Accordingly, radial and circumferential strain and radial and circumferential strain synchrony were measured with speckle‐tracking echocardiography during biventricular pacing in a model of left ventricular (LV) volume overload. Methods: Heart block was established in 4 open‐chest anesthetized pigs. Left ventricular volume overload was induced with an ascending aorta‐LV apex conduit. Measurements included cardiac output by an aortic flow probe, the maximum derivative of LV pressure versus time (dP/dtmax ), and transseptal pressure synchrony. Biventricular pacing was performed for combinations of 3 interventricular delays and 3 LV pacing sites. Speckle‐tracking echocardiographic analysis was applied to short‐axis images at the midpapillary LV for 9 pacing combinations. Strain and synchrony parameters were correlated with hemodynamics. Results: Increased cardiac output correlated with improved global circumferential strain ( P = .002) but not changes in global radial strain or radial strain synchrony. Increased LV dP/dtmax was associated with improved circumferential strain in the septum ( P < .001) and radial strain in the lateral wall ( P = .046). Improved transseptal pressure synchrony was associated with improved global circumferential strain, but primarily in the septum ( P < .001).Abstract : Objectives: Biventricular pacing may ameliorate symptoms of acute heart failure. Speckle‐tracking echocardiography can assess cardiac function to elucidate mechanisms of benefit. Accordingly, radial and circumferential strain and radial and circumferential strain synchrony were measured with speckle‐tracking echocardiography during biventricular pacing in a model of left ventricular (LV) volume overload. Methods: Heart block was established in 4 open‐chest anesthetized pigs. Left ventricular volume overload was induced with an ascending aorta‐LV apex conduit. Measurements included cardiac output by an aortic flow probe, the maximum derivative of LV pressure versus time (dP/dtmax ), and transseptal pressure synchrony. Biventricular pacing was performed for combinations of 3 interventricular delays and 3 LV pacing sites. Speckle‐tracking echocardiographic analysis was applied to short‐axis images at the midpapillary LV for 9 pacing combinations. Strain and synchrony parameters were correlated with hemodynamics. Results: Increased cardiac output correlated with improved global circumferential strain ( P = .002) but not changes in global radial strain or radial strain synchrony. Increased LV dP/dtmax was associated with improved circumferential strain in the septum ( P < .001) and radial strain in the lateral wall ( P = .046). Improved transseptal pressure synchrony was associated with improved global circumferential strain, but primarily in the septum ( P < .001). Aortic valve closure occurred before peak radial strain in 62% of beats and before peak circumferential strain in 6%. Conclusions: During acute LV volume overload, hemodynamic improvement with biventricular pacing was associated with improved circumferential strain primarily in the septum. Radial strain and radial strain synchrony did not correlate with improvement, possibly due to delayed systolic contraction. An increase in circumferential strain in the septum associated with optimum transseptal pressure synchrony suggested improvement by interventricular assist from the right ventricle. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 32:Number 4(2013)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 32:Number 4(2013)
- Issue Display:
- Volume 32, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 32
- Issue:
- 4
- Issue Sort Value:
- 2013-0032-0004-0000
- Page Start:
- 675
- Page End:
- 682
- Publication Date:
- 2013-04-01
- Subjects:
- biventricular pacing -- speckle-tracking echocardiography -- volume overload
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.7863/jum.2013.32.4.675 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2242.xml