Reliability Assessment of Various Sonographic Techniques for Evaluating Carpal Tunnel Syndrome. (9th October 2015)
- Record Type:
- Journal Article
- Title:
- Reliability Assessment of Various Sonographic Techniques for Evaluating Carpal Tunnel Syndrome. (9th October 2015)
- Main Title:
- Reliability Assessment of Various Sonographic Techniques for Evaluating Carpal Tunnel Syndrome
- Authors:
- Junck, Anthony D.
Escobedo, Eva M.
Lipa, Bethany M.
Cronan, Michael
Anthonisen, Colleen
Poltavskiy, Eduard
Bang, Heejung
Han, Jay J. - Abstract:
- Abstract : Objectives: The aim of this study was to determine the intra‐ and inter‐rater reliability of sonographic measurements of the median nerve cross‐sectional area in individuals with carpal tunnel syndrome and healthy control participants. Methods: The median nerve cross‐sectional area was evaluated by sonography in 18 participants with carpal tunnel syndrome (18 upper extremities) and 9 control participants (18 upper extremities) at 2 visits 1 week apart. Two examiners, both blinded to the presence or absence of carpal tunnel syndrome, captured independent sonograms of the median nerve at the levels of the carpal tunnel inlet, pronator quadratus, and mid‐forearm. The cross‐sectional area was later measured by each examiner independently. Each also traced images that were captured by the other examiner. Results: Both the intra‐ and inter‐rater reliability rates were highest for images taken at the carpal tunnel inlet (radiologist, r = 0.86; sonographer, r = 0.87; inter‐rater, r = 0.95; all P < .0001), whereas they was lowest for the pronator quadratus ( r = 0.49, 0.29, and 0.72, respectively; all P < .0001). At the mid‐forearm, the intra‐rater reliability was lower for both the radiologist and sonographer, whereas the inter‐rater reliability was relatively high ( r = 0.54, 0.55, and 0.81; all P < .0001). Tracing of captured images by different examiners showed high concordance for the median cross‐sectional area at the carpal tunnel inlet ( r = 0.96–0.98; P < .0001).Abstract : Objectives: The aim of this study was to determine the intra‐ and inter‐rater reliability of sonographic measurements of the median nerve cross‐sectional area in individuals with carpal tunnel syndrome and healthy control participants. Methods: The median nerve cross‐sectional area was evaluated by sonography in 18 participants with carpal tunnel syndrome (18 upper extremities) and 9 control participants (18 upper extremities) at 2 visits 1 week apart. Two examiners, both blinded to the presence or absence of carpal tunnel syndrome, captured independent sonograms of the median nerve at the levels of the carpal tunnel inlet, pronator quadratus, and mid‐forearm. The cross‐sectional area was later measured by each examiner independently. Each also traced images that were captured by the other examiner. Results: Both the intra‐ and inter‐rater reliability rates were highest for images taken at the carpal tunnel inlet (radiologist, r = 0.86; sonographer, r = 0.87; inter‐rater, r = 0.95; all P < .0001), whereas they was lowest for the pronator quadratus ( r = 0.49, 0.29, and 0.72, respectively; all P < .0001). At the mid‐forearm, the intra‐rater reliability was lower for both the radiologist and sonographer, whereas the inter‐rater reliability was relatively high ( r = 0.54, 0.55, and 0.81; all P < .0001). Tracing of captured images by different examiners showed high concordance for the median cross‐sectional area at the carpal tunnel inlet ( r = 0.96–0.98; P < .0001). Conclusions: The highest intra‐ and inter‐rater reliability was found at the carpal tunnel inlet. The results also demonstrate that tracing of the median nerve cross‐sectional area from captured images by different examiners does not contribute significantly to measurement variability. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 34:Number 11(2015)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 34:Number 11(2015)
- Issue Display:
- Volume 34, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2015-0034-0011-0000
- Page Start:
- 2077
- Page End:
- 2088
- Publication Date:
- 2015-10-09
- Subjects:
- carpal tunnel syndrome -- cross‐sectional area -- median nerve -- musculoskeletal ultrasound -- reliability -- sonography
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.7863/ultra.15.01069 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1117.xml