Ex Vivo Assessment of Sentinel Lymph Nodes in Breast Cancer Using Shear Wave Elastography. (29th December 2015)
- Record Type:
- Journal Article
- Title:
- Ex Vivo Assessment of Sentinel Lymph Nodes in Breast Cancer Using Shear Wave Elastography. (29th December 2015)
- Main Title:
- Ex Vivo Assessment of Sentinel Lymph Nodes in Breast Cancer Using Shear Wave Elastography
- Authors:
- Kilic, Fahrettin
Velidedeoglu, Mehmet
Ozturk, Tulin
Kandemirli, Sedat Giray
Dikici, Atilla Suleyman
Er, Mehmet Emin
Aydogan, Fatih
Kantarci, Fatih
Yilmaz, Mehmet Halit - Abstract:
- Abstract : Objectives: Axillary lymph node status is one of the important prognostic factors in early‐stage breast cancer. Despite the combined use of sonography, fine‐needle aspiration, and sentinel lymph node (SLN) dissection, there is a gap between the potential effectiveness of those techniques and current success to determine the axillary lymph node status. The main aim of this study was to evaluate the baseline accuracy of shear wave elastography for differentiation of benign versus malignant SLNs in an ex vivo artifact‐free environment. Methods: Thirty patients with breast cancer scheduled for SLN dissection were enrolled prospectively after informed consent and Institutional Review Board approval were obtained. After dissection, lymph nodes were embedded in ultrasound gel and examined with grayscale sonography and shear wave elastography. Findings were compared to histopathologic results. Results: A total of 64 SLNs obtained from the 30 patients were evaluated. Twelve of them (18.8%) were metastatic, and 52 (81.2%) were benign. The mean cortical thickness (benign versus metastatic, 1.6 versus 4.4 mm), short‐axis length (4.63 versus 7.50 mm), cortical stiffness (10.7 versus 25.5 kPa), and hilar stiffness (7.5 versus 11.3 kPa) were statistically higher in metastatic lymph nodes ( P ≤ .02). Area under the receiver operator characteristic curve values for these variables were 0.814, 0.768, 0.786, and 0.759, respectively. Cortical thickness was found to have the highestAbstract : Objectives: Axillary lymph node status is one of the important prognostic factors in early‐stage breast cancer. Despite the combined use of sonography, fine‐needle aspiration, and sentinel lymph node (SLN) dissection, there is a gap between the potential effectiveness of those techniques and current success to determine the axillary lymph node status. The main aim of this study was to evaluate the baseline accuracy of shear wave elastography for differentiation of benign versus malignant SLNs in an ex vivo artifact‐free environment. Methods: Thirty patients with breast cancer scheduled for SLN dissection were enrolled prospectively after informed consent and Institutional Review Board approval were obtained. After dissection, lymph nodes were embedded in ultrasound gel and examined with grayscale sonography and shear wave elastography. Findings were compared to histopathologic results. Results: A total of 64 SLNs obtained from the 30 patients were evaluated. Twelve of them (18.8%) were metastatic, and 52 (81.2%) were benign. The mean cortical thickness (benign versus metastatic, 1.6 versus 4.4 mm), short‐axis length (4.63 versus 7.50 mm), cortical stiffness (10.7 versus 25.5 kPa), and hilar stiffness (7.5 versus 11.3 kPa) were statistically higher in metastatic lymph nodes ( P ≤ .02). Area under the receiver operator characteristic curve values for these variables were 0.814, 0.768, 0.786, and 0.759, respectively. Cortical thickness was found to have the highest diagnostic performance, followed by cortical stiffness. Conclusions: Shear wave elastography can be used with grayscale sonography for evaluation of cases to decide on needle biopsy sampling. However, it cannot be used as a replacement for fine‐needle aspiration or SLN dissection. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 35:Number 2(2016)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 35:Number 2(2016)
- Issue Display:
- Volume 35, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 35
- Issue:
- 2
- Issue Sort Value:
- 2016-0035-0002-0000
- Page Start:
- 271
- Page End:
- 277
- Publication Date:
- 2015-12-29
- Subjects:
- breast cancer -- breast ultrasound -- fine-needle aspiration -- elastography -- lymph node dissection -- sentinel lymph node biopsy -- sonography
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.7863/ultra.15.03039 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 432.xml