A New Reliable Method for Evaluating Gallbladder Dynamics: The 3‐Dimensional Sonographic Examination. (6th January 2016)
- Record Type:
- Journal Article
- Title:
- A New Reliable Method for Evaluating Gallbladder Dynamics: The 3‐Dimensional Sonographic Examination. (6th January 2016)
- Main Title:
- A New Reliable Method for Evaluating Gallbladder Dynamics
- Authors:
- Serra, Carla
Pallotti, Francesca
Bortolotti, Mauro
Caputo, Carla
Felicani, Cristina
De Giorgio, Roberto
Barbara, Giovanni
Nardi, Elena
Labate, Antonio Maria Morselli - Abstract:
- Abstract : Objectives: The purpose of this study was to compare conventional 2‐dimensional (2D) B‐mode sonography with 3‐dimensional (3D) sonography for assessing gallbladder volume and contractility. Methods: Gallbladder volume and contractility were evaluated in 32 healthy volunteers after fasting and abstinence from smoking for 8 hours and after a standardized balanced liquid meal. The gallbladder was evaluated with 2D sonography (with the use of the ellipsoid method) and with 3D sonography using a volumetric matrix probe. Both measurements were made by an operator who was skilled in sonography and an unskilled operator. The group of volunteers was subdivided into 2 subgroups including 16 participants, which represented the "2 moments" of acquisition by the techniques, particularly for the unskilled operator. Results: The postprandial volumes obtained with 3D sonography were significantly lower in comparison to the volumes obtained with 2D sonography ( P = .013), and there was a significant difference between the measurements made by the skilled and unskilled operators only for 2D sonography ( P < .001), whereas between the 2 moments of acquisition by the 3D technique, there was no significant difference. The reproducibility of the technique for evaluation of gallbladder volumes was higher for 3D sonography than 2D sonography, particularly for the postprandial evaluation. Conclusions: The new 3D sonographic method using a volumetric matrix probe is a simple, reliable, andAbstract : Objectives: The purpose of this study was to compare conventional 2‐dimensional (2D) B‐mode sonography with 3‐dimensional (3D) sonography for assessing gallbladder volume and contractility. Methods: Gallbladder volume and contractility were evaluated in 32 healthy volunteers after fasting and abstinence from smoking for 8 hours and after a standardized balanced liquid meal. The gallbladder was evaluated with 2D sonography (with the use of the ellipsoid method) and with 3D sonography using a volumetric matrix probe. Both measurements were made by an operator who was skilled in sonography and an unskilled operator. The group of volunteers was subdivided into 2 subgroups including 16 participants, which represented the "2 moments" of acquisition by the techniques, particularly for the unskilled operator. Results: The postprandial volumes obtained with 3D sonography were significantly lower in comparison to the volumes obtained with 2D sonography ( P = .013), and there was a significant difference between the measurements made by the skilled and unskilled operators only for 2D sonography ( P < .001), whereas between the 2 moments of acquisition by the 3D technique, there was no significant difference. The reproducibility of the technique for evaluation of gallbladder volumes was higher for 3D sonography than 2D sonography, particularly for the postprandial evaluation. Conclusions: The new 3D sonographic method using a volumetric matrix probe is a simple, reliable, and more reproducible technique than conventional 2D sonography, even if performed by an unskilled operator, and it allows a reliable stimulation test for a gallbladder dynamic study. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 35:Number 2(2016)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 35:Number 2(2016)
- Issue Display:
- Volume 35, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 35
- Issue:
- 2
- Issue Sort Value:
- 2016-0035-0002-0000
- Page Start:
- 297
- Page End:
- 304
- Publication Date:
- 2016-01-06
- Subjects:
- cholecystokinetic stimulation -- gallbladder contraction -- gallbladder volume -- gastrointestinal ultrasound -- 3‐dimensional sonography
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.7863/ultra.14.10033 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 432.xml