High-speed video analysis of forward and backward spattered blood droplets. (July 2017)
- Record Type:
- Journal Article
- Title:
- High-speed video analysis of forward and backward spattered blood droplets. (July 2017)
- Main Title:
- High-speed video analysis of forward and backward spattered blood droplets
- Authors:
- Comiskey, P.M.
Yarin, A.L.
Attinger, D. - Abstract:
- Highlights: High-speed videos of blood spatter due to a gunshot were analyzed. Maximal blood velocity can be about twice as high in forward vs. backward spatter. Side-view area of the droplets is roughly the same for forward and backward spatter. More blood droplets are produced in forward spatter than in backward. Abstract: High-speed videos of blood spatter due to a gunshot taken by the Ames Laboratory Midwest Forensics Resource Center (MFRC) [1] are analyzed. The videos used in this analysis were focused on a variety of targets hit by a bullet which caused either forward, backward, or both types of blood spatter. The analysis process utilized particle image velocimetry (PIV) and particle analysis software to measure drop velocities as well as the distributions of the number of droplets and their respective side view area. The results of this analysis revealed that the maximal velocity in the forward spatter can be about 47 ± 5 m/s and for the backward spatter – about 24 ± 8 m/s. Moreover, our measurements indicate that the number of droplets produced is larger in forward spatter than it is in backward spatter. In the forward and backward spatter the droplet area in the side-view images is approximately the same. The upper angles of the close-to-cone domain in which droplets are issued in forward and backward spatter are, 27 ± 9° and 57 ± 7°, respectively, whereas the lower angles of the close-to-cone domain are 28 ± 12° and 30 ± 18°, respectively. The inclination angle ofHighlights: High-speed videos of blood spatter due to a gunshot were analyzed. Maximal blood velocity can be about twice as high in forward vs. backward spatter. Side-view area of the droplets is roughly the same for forward and backward spatter. More blood droplets are produced in forward spatter than in backward. Abstract: High-speed videos of blood spatter due to a gunshot taken by the Ames Laboratory Midwest Forensics Resource Center (MFRC) [1] are analyzed. The videos used in this analysis were focused on a variety of targets hit by a bullet which caused either forward, backward, or both types of blood spatter. The analysis process utilized particle image velocimetry (PIV) and particle analysis software to measure drop velocities as well as the distributions of the number of droplets and their respective side view area. The results of this analysis revealed that the maximal velocity in the forward spatter can be about 47 ± 5 m/s and for the backward spatter – about 24 ± 8 m/s. Moreover, our measurements indicate that the number of droplets produced is larger in forward spatter than it is in backward spatter. In the forward and backward spatter the droplet area in the side-view images is approximately the same. The upper angles of the close-to-cone domain in which droplets are issued in forward and backward spatter are, 27 ± 9° and 57 ± 7°, respectively, whereas the lower angles of the close-to-cone domain are 28 ± 12° and 30 ± 18°, respectively. The inclination angle of the bullet as it penetrates the target is seen to play a large role in the directional preference of the spattered blood. Also, muzzle gases, bullet impact angle, as well as the aerodynamic wake of the bullet are seen to greatly influence the flight of the droplets. The intent of this investigation is to provide a quantitative basis for current and future research on bloodstain pattern analysis (BPA) of either forward or backward blood spatter due to a gunshot. … (more)
- Is Part Of:
- Forensic science international. Volume 276(2017)
- Journal:
- Forensic science international
- Issue:
- Volume 276(2017)
- Issue Display:
- Volume 276, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 276
- Issue:
- 2017
- Issue Sort Value:
- 2017-0276-2017-0000
- Page Start:
- 134
- Page End:
- 141
- Publication Date:
- 2017-07
- Subjects:
- Bloodstain pattern analysis -- Forward spatter -- Backward spatter -- Gunshot -- High-speed video analysis -- Particle image velocimetry
Medical jurisprudence -- Periodicals
Chemistry, Forensic -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Chimie légale -- Périodiques
Gerechtelijke geneeskunde
Gerechtelijke chemie
Gerechtelijke psychiatrie
Chemistry, Forensic
Medical jurisprudence
Electronic journals
Periodicals
Electronic journals
614.1 - Journal URLs:
- http://www.clinicalkey.com.au/dura/browse/journalIssue/03790738 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03790738 ↗
http://www.sciencedirect.com/science/journal/03790738 ↗
http://infotrac.galegroup.com/itw/infomark/1/1/1/purl=rc18_EAIM_0__jn+%22Forensic+Science+International%22?sw_aep=stand ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.forsciint.2017.04.016 ↗
- Languages:
- English
- ISSNs:
- 0379-0738
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3987.764000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 68.xml