L sub-shell fluorescence cross-section measurements for elements, Z = 62–67, at tuned photon energies. (September 2017)
- Record Type:
- Journal Article
- Title:
- L sub-shell fluorescence cross-section measurements for elements, Z = 62–67, at tuned photon energies. (September 2017)
- Main Title:
- L sub-shell fluorescence cross-section measurements for elements, Z = 62–67, at tuned photon energies
- Authors:
- Bansal, Himani
Tiwari, M.K.
Mittal, Raj - Abstract:
- Highlights: L sub-shell XRF cross-sections for 6 elements with Z = 62–67. Three synchrotron photon energies at 0.1 keV intervals in each region; > EL1, < EL1 & >EL2 and 2 & >EL3 ; ELi absorption edges. Comparison of measured cross-sections with calculated theoretical values. fij and ωi are evaluated from measured XRF cross-sections and compared with their literature values. From trends of total measured L XRF cross-sections with photon energy results were found affected by the 4f electron filling in the elements. Abstract: L sub-shell X-ray fluorescence (XRF) cross-sections for 6 elements with Z = 62-67 have been measured at tuned photon energies on synchrotron Beamline-16, Indus-2, RRCAT, India. Three incident photon energies at the intervals of 0.1 keV were tuned in each region; > EL1, < EL1 & >EL2 and 2 & >EL3 where ELi are Li (i = 1-3) absorption edge energies of element. No single measurement is available in literature for present incident photon energies and elements, therefore, certainty and reliability of the measurements have been judged from three different aspects. One, from comparison of measured cross-sections with calculated theoretical values. Second, evaluation of Coster-Kronig yield ( fij 's ) and fluorescence yield ( ωi 's ) fine parameters from measured XRF cross-sections with formulations derived from total intensity of X-rays originating from individual sub-shells that generated a data set for fij 's and ωi 's of six elements for comparison withHighlights: L sub-shell XRF cross-sections for 6 elements with Z = 62–67. Three synchrotron photon energies at 0.1 keV intervals in each region; > EL1, < EL1 & >EL2 and 2 & >EL3 ; ELi absorption edges. Comparison of measured cross-sections with calculated theoretical values. fij and ωi are evaluated from measured XRF cross-sections and compared with their literature values. From trends of total measured L XRF cross-sections with photon energy results were found affected by the 4f electron filling in the elements. Abstract: L sub-shell X-ray fluorescence (XRF) cross-sections for 6 elements with Z = 62-67 have been measured at tuned photon energies on synchrotron Beamline-16, Indus-2, RRCAT, India. Three incident photon energies at the intervals of 0.1 keV were tuned in each region; > EL1, < EL1 & >EL2 and 2 & >EL3 where ELi are Li (i = 1-3) absorption edge energies of element. No single measurement is available in literature for present incident photon energies and elements, therefore, certainty and reliability of the measurements have been judged from three different aspects. One, from comparison of measured cross-sections with calculated theoretical values. Second, evaluation of Coster-Kronig yield ( fij 's ) and fluorescence yield ( ωi 's ) fine parameters from measured XRF cross-sections with formulations derived from total intensity of X-rays originating from individual sub-shells that generated a data set for fij 's and ωi 's of six elements for comparison with available theoretical/empirical/experimental values. Third, from trends of total measured L XRF cross-sections with photon energy for the elements. The results were found affected by the 4f electron filling in the elements. … (more)
- Is Part Of:
- Journal of quantitative spectroscopy & radiative transfer. Volume 199(2017)
- Journal:
- Journal of quantitative spectroscopy & radiative transfer
- Issue:
- Volume 199(2017)
- Issue Display:
- Volume 199, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 199
- Issue:
- 2017
- Issue Sort Value:
- 2017-0199-2017-0000
- Page Start:
- 93
- Page End:
- 102
- Publication Date:
- 2017-09
- Subjects:
- Selective L sub-shell excitation -- X-ray fluorescence cross-sections -- Coster-Kronig yields -- fluorescence yields -- Synchrotron Photons
Spectrum analysis -- Periodicals
Radiation -- Periodicals
Analyse spectrale -- Périodiques
Rayonnement -- Périodiques
Radiation
Spectrum analysis
Periodicals
543.0858 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00224073 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jqsrt.2017.05.007 ↗
- Languages:
- English
- ISSNs:
- 0022-4073
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5043.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 528.xml