Micro-computed tomography, scanning electron microscopy and energy X-ray spectroscopy studies of facet joint degeneration: A comparison to clinical imaging. (September 2017)
- Record Type:
- Journal Article
- Title:
- Micro-computed tomography, scanning electron microscopy and energy X-ray spectroscopy studies of facet joint degeneration: A comparison to clinical imaging. (September 2017)
- Main Title:
- Micro-computed tomography, scanning electron microscopy and energy X-ray spectroscopy studies of facet joint degeneration: A comparison to clinical imaging
- Authors:
- Goehre, Felix
Ludtka, Christopher
Hamperl, Melanie
Friedmann, Andrea
Straube, Anja
Mendel, Thomas
Heilmann, Andreas
Meisel, Hans Jörg
Schwan, Stefan - Abstract:
- Highlights: Facet joint tissue degeneration characterized by micro CT, SEM and EDX spectroscopy. Evaluated composition, layer thicknesses, cell density, bone portion and porosity. Samples had damaged cartilage, more chondrocytes, trabecular bone, and calcification. Microstructural damage did not correlate with clinical data (age, sex, BMI, etc.). Abstract: Segmental degeneration in the human lumbar spine affects both the intervertebral discs and facet joints. Facet joint degeneration not only affects the cartilage surface, but also alters the cellular properties of the cartilage tissue and the structure of the subchondral bone. The primary focus of this study is the investigation of these microstructural changes that are caused by facet joint degeneration. Microstructural analyses of degenerated facet joint samples, obtained from patients following operative lumbar interbody fusion, have not previously been extensively investigated. This study analyzes human facet joint samples from the inferior articular process using scanning electron microscopy, micro-computed tomography, and energy dispersive X-ray spectroscopy to evaluate parameters of interest in facet joint degeneration such as elemental composition, cartilage layer thickness and cell density, calcification zone thickness, subchondral bone portion, and trabecular bone porosity. These microstructural analyses demonstrate fragmentation, cracking, and destruction of the cartilage layer, a thickened calcification zone,Highlights: Facet joint tissue degeneration characterized by micro CT, SEM and EDX spectroscopy. Evaluated composition, layer thicknesses, cell density, bone portion and porosity. Samples had damaged cartilage, more chondrocytes, trabecular bone, and calcification. Microstructural damage did not correlate with clinical data (age, sex, BMI, etc.). Abstract: Segmental degeneration in the human lumbar spine affects both the intervertebral discs and facet joints. Facet joint degeneration not only affects the cartilage surface, but also alters the cellular properties of the cartilage tissue and the structure of the subchondral bone. The primary focus of this study is the investigation of these microstructural changes that are caused by facet joint degeneration. Microstructural analyses of degenerated facet joint samples, obtained from patients following operative lumbar interbody fusion, have not previously been extensively investigated. This study analyzes human facet joint samples from the inferior articular process using scanning electron microscopy, micro-computed tomography, and energy dispersive X-ray spectroscopy to evaluate parameters of interest in facet joint degeneration such as elemental composition, cartilage layer thickness and cell density, calcification zone thickness, subchondral bone portion, and trabecular bone porosity. These microstructural analyses demonstrate fragmentation, cracking, and destruction of the cartilage layer, a thickened calcification zone, localized calcification areas, and cell cluster formation as pathological manifestations of facet joint degeneration. The detailed description of these microstructural changes is critical for a comprehensive understanding of the pathology of facet joint degeneration, as well as the subsequent development and efficacy analysis of regenerative treatment strategies. … (more)
- Is Part Of:
- Micron. Volume 100(2017)
- Journal:
- Micron
- Issue:
- Volume 100(2017)
- Issue Display:
- Volume 100, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 100
- Issue:
- 2017
- Issue Sort Value:
- 2017-0100-2017-0000
- Page Start:
- 50
- Page End:
- 59
- Publication Date:
- 2017-09
- Subjects:
- Computed tomography -- Facet joint -- Human lumbar spine -- Scanning electron microscopy -- Structure analysis
Microscopy -- Periodicals
Electron Probe Microanalysis -- Periodicals
Microscopy -- Periodicals
Microscopie -- Périodiques
Microscopy
Periodicals
502.82 - Journal URLs:
- http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.sciencedirect.com/science/journal/09684328 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.micron.2017.04.011 ↗
- Languages:
- English
- ISSNs:
- 0968-4328
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5759.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2274.xml