Microwave spectrometry for the evaluation of the structural integrity of metallic stents. Issue 4 (5th March 2014)
- Record Type:
- Journal Article
- Title:
- Microwave spectrometry for the evaluation of the structural integrity of metallic stents. Issue 4 (5th March 2014)
- Main Title:
- Microwave spectrometry for the evaluation of the structural integrity of metallic stents
- Authors:
- Arauz‐Garofalo, Gianluca
López‐Domínguez, Víctor
Hernàndez, Joan Manel
Rodríguez‐Leor, Oriol
Bayés‐Genís, Antoni
O'Callaghan, Juan M.
García‐Santiago, Antoni
Tejada, Javier - Abstract:
- Abstract : Purpose: : To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: : Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360°, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water‐based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: : The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures.Abstract : Purpose: : To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: : Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360°, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water‐based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: : The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: : The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verification in a more relevant phantom is required in order to foresee the real potential of this approach. … (more)
- Is Part Of:
- Medical physics. Volume 41:Issue 4(2014)
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 4(2014)
- Issue Display:
- Volume 41, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 4
- Issue Sort Value:
- 2014-0041-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-03-05
- Subjects:
- Biomedical engineering -- Fatigue, corrosion fatigue, embrittlement, cracking, fracture, and failure -- Nondestructive testing: electromagnetic testing, eddy‐current testing
fracture -- materials testing -- microwave spectra -- permittivity -- phantoms -- shrinkage -- stents
microwaves -- stents -- coronary artery disease -- stent fracture -- stent recoil
Devices providing patency to, or preventing collapsing of, tubular structures of the body, e.g. stents -- Investigating or analysing materials by determining their chemical or physical properties
Microwave spectra -- Antennas -- Microwaves -- Geologic fractures -- Absorption spectra -- Statistical methods -- Water vapor -- Medical imaging -- Spectral properties -- Permittivity
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4866881 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 479.xml