Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex. (30th August 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex. (30th August 2016)
- Main Title:
- Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex
- Authors:
- Goreczny, Sebastian
Qureshi, Shakeel A.
Rosenthal, Eric
Krasemann, Thomas
Nassar, Mohamed S.
Anderson, David R.
Morgan, Gareth J. - Abstract:
- Abstract: Objectives: We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. Background: The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. Methods: We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. Results: In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Conclusions: Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groupsAbstract: Objectives: We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. Background: The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. Methods: We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. Results: In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Conclusions: Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents. … (more)
- Is Part Of:
- Cardiology in the young. Volume 27:Number 5(2017)
- Journal:
- Cardiology in the young
- Issue:
- Volume 27:Number 5(2017)
- Issue Display:
- Volume 27, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 27
- Issue:
- 5
- Issue Sort Value:
- 2017-0027-0005-0000
- Page Start:
- 837
- Page End:
- 845
- Publication Date:
- 2016-08-30
- Subjects:
- Hypoplastic left heart syndrome, -- hybrid procedure, -- ductal stenting
Pediatric cardiology -- Periodicals
618.9212 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=CTY ↗
- DOI:
- 10.1017/S1047951116001347 ↗
- Languages:
- English
- ISSNs:
- 1047-9511
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital Store
- Ingest File:
- 447.xml