A Monte Carlo method and finite volume method coupled optical simulation method for parabolic trough solar collectors. (1st September 2017)
- Record Type:
- Journal Article
- Title:
- A Monte Carlo method and finite volume method coupled optical simulation method for parabolic trough solar collectors. (1st September 2017)
- Main Title:
- A Monte Carlo method and finite volume method coupled optical simulation method for parabolic trough solar collectors
- Authors:
- Liang, Hongbo
Fan, Man
You, Shijun
Zheng, Wandong
Zhang, Huan
Ye, Tianzhen
Zheng, Xuejing - Abstract:
- Highlights: Four optical models for parabolic trough solar collectors were compared in detail. Characteristics of Monte Carlo Method and Finite Volume Method were discussed. A novel method was presented combining advantages of different models. The method was suited to optical analysis of collectors with different geometries. A new kind of cavity receiver was simulated depending on the novel method. Abstract: The PTC (parabolic trough solar collector) is widely used for space heating, heat-driven refrigeration, solar power, etc. The concentrated solar radiation is the only energy source for a PTC, thus its optical performance significantly affects the collector efficiency. In this study, four different optical models were constructed, validated and compared in detail. On this basis, a novel coupled method was presented by combining advantages of these models, which was suited to carry out a mass of optical simulations of collectors with different geometrical parameters rapidly and accurately. Based on these simulation results, the optimal configuration of a collector with highest efficiency can be determined. Thus, this method was useful for collector optimization and design. In the four models, MCM (Monte Carlo Method) and FVM (Finite Volume Method) were used to initialize photons distribution, as well as CPEM (Change Photon Energy Method) and MCM were adopted to describe the process of reflecting, transmitting and absorbing. For simulating reflection, transmission andHighlights: Four optical models for parabolic trough solar collectors were compared in detail. Characteristics of Monte Carlo Method and Finite Volume Method were discussed. A novel method was presented combining advantages of different models. The method was suited to optical analysis of collectors with different geometries. A new kind of cavity receiver was simulated depending on the novel method. Abstract: The PTC (parabolic trough solar collector) is widely used for space heating, heat-driven refrigeration, solar power, etc. The concentrated solar radiation is the only energy source for a PTC, thus its optical performance significantly affects the collector efficiency. In this study, four different optical models were constructed, validated and compared in detail. On this basis, a novel coupled method was presented by combining advantages of these models, which was suited to carry out a mass of optical simulations of collectors with different geometrical parameters rapidly and accurately. Based on these simulation results, the optimal configuration of a collector with highest efficiency can be determined. Thus, this method was useful for collector optimization and design. In the four models, MCM (Monte Carlo Method) and FVM (Finite Volume Method) were used to initialize photons distribution, as well as CPEM (Change Photon Energy Method) and MCM were adopted to describe the process of reflecting, transmitting and absorbing. For simulating reflection, transmission and absorption, CPEM was more efficient than MCM, so it was utilized in the coupled method. For photons distribution initialization, FVM saved running time and computation effort, whereas it needed suitable grid configuration. MCM only required a total number of rays for simulation, whereas it needed higher computing cost and its results fluctuated in multiple runs. In the novel coupled method, the grid configuration for FVM was optimized according to the "true values" from MCM of collectors with the maximum geometry difference. Following this, the initialization of photons distribution of collectors with different geometries were conducted with FVM. To demonstrate this coupled model in real practice, performance analysis of a kind of cavity receiver for PTCs was carried out. The judgment of collectors with maximum geometry difference were worth investigating further in the future work. … (more)
- Is Part Of:
- Applied energy. Volume 201(2017)
- Journal:
- Applied energy
- Issue:
- Volume 201(2017)
- Issue Display:
- Volume 201, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 201
- Issue:
- 2017
- Issue Sort Value:
- 2017-0201-2017-0000
- Page Start:
- 60
- Page End:
- 68
- Publication Date:
- 2017-09-01
- Subjects:
- Parabolic trough solar collector -- Monte Carlo method -- Finite volume method -- Ray tracing -- Concentrated heat flux distribution
Power (Mechanics) -- Periodicals
Energy conservation -- Periodicals
Energy conversion -- Periodicals
621.042 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03062619 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apenergy.2017.05.047 ↗
- Languages:
- English
- ISSNs:
- 0306-2619
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1572.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2088.xml