Practical Assessment of Bronchoscopically Inserted Fiducial Markers for Image Guidance in Stereotactic Lung Radiotherapy. Issue 8 (August 2016)
- Record Type:
- Journal Article
- Title:
- Practical Assessment of Bronchoscopically Inserted Fiducial Markers for Image Guidance in Stereotactic Lung Radiotherapy. Issue 8 (August 2016)
- Main Title:
- Practical Assessment of Bronchoscopically Inserted Fiducial Markers for Image Guidance in Stereotactic Lung Radiotherapy
- Authors:
- Jackson, Price
Steinfort, Daniel P.
Kron, Tomas
Siva, Shankar - Abstract:
- ABSTRACT : Introduction: : Stereotactic radiotherapy is a high‐dose precision technique necessitating accurate target visualization through either cone beam computed tomography (CBCT) or planar imaging with implanted fiducial markers. We have investigated the properties for image guidance using fiducial markers implanted through minimally invasive bronchoscopy. Methods: : Two fiducial marker types were implanted endobronchially in 10 patients undergoing radical radiation treatment for non–small cell lung cancer (eight using Visicoil linear fiducial markers [IBA Dosimetry GmbH, Schwarzenbruck Germany] and two using superDimension and superLock two‐band markers [Covidien Inc., Minneapolis, MN]). Patients underwent four‐dimensional computed tomography imaging for treatment planning and after completion of treatment to investigate marker movement. As part of the image guidance assessment, megavolt electronic portal images (EPIs) were acquired in addition to kilovolt planar and CBCT (Varian Medical Systems, Palo Alto, CA) images. Results: : In two of 10 patients (both receiving Visicoil markers), marker migration was observed before treatment. In patients with stable markers, both types were clearly visible in planar kilovolt imaging; however, in EPIs the markers could be detected only in selected beam directions in which bony interference was minimal. Diagnostic computed tomography scanning was able to demonstrate the markers with clarity, but significant starring artifacts wereABSTRACT : Introduction: : Stereotactic radiotherapy is a high‐dose precision technique necessitating accurate target visualization through either cone beam computed tomography (CBCT) or planar imaging with implanted fiducial markers. We have investigated the properties for image guidance using fiducial markers implanted through minimally invasive bronchoscopy. Methods: : Two fiducial marker types were implanted endobronchially in 10 patients undergoing radical radiation treatment for non–small cell lung cancer (eight using Visicoil linear fiducial markers [IBA Dosimetry GmbH, Schwarzenbruck Germany] and two using superDimension and superLock two‐band markers [Covidien Inc., Minneapolis, MN]). Patients underwent four‐dimensional computed tomography imaging for treatment planning and after completion of treatment to investigate marker movement. As part of the image guidance assessment, megavolt electronic portal images (EPIs) were acquired in addition to kilovolt planar and CBCT (Varian Medical Systems, Palo Alto, CA) images. Results: : In two of 10 patients (both receiving Visicoil markers), marker migration was observed before treatment. In patients with stable markers, both types were clearly visible in planar kilovolt imaging; however, in EPIs the markers could be detected only in selected beam directions in which bony interference was minimal. Diagnostic computed tomography scanning was able to demonstrate the markers with clarity, but significant starring artifacts were observed in CBCT. This was particularly problematic in patients with some lateral component of tumor motion during breathing. Conclusions: : The potential for fiducial migration must be considered and investigated if bronchoscopic implantation of fiducial markers is performed. The choice of marker is a compromise between trying to minimize CBCT artifacts while enabling visualization in EPI imaging, which is an ideal tool to verify gated radiotherapy delivery. … (more)
- Is Part Of:
- Journal of thoracic oncology. Volume 11:Issue 8(2016)
- Journal:
- Journal of thoracic oncology
- Issue:
- Volume 11:Issue 8(2016)
- Issue Display:
- Volume 11, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 8
- Issue Sort Value:
- 2016-0011-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-08
- Subjects:
- Fiducial -- Endobronchial -- Image guidance -- SBRT -- SABR -- EBUS
Chest -- Cancer -- Periodicals
Thoracic Neoplasms -- Periodicals
616.99494005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243894-000000000-00000 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01243894-200601000-00001 ↗
http://www.sciencedirect.com/science/journal/15560864/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1016/j.jtho.2016.04.016 ↗
- Languages:
- English
- ISSNs:
- 1556-0864
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.124000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 673.xml