A feasibility study of digital single-operator cholangioscopy for diagnostic and therapeutic procedure (with videos). Issue 15 (April 2017)
- Record Type:
- Journal Article
- Title:
- A feasibility study of digital single-operator cholangioscopy for diagnostic and therapeutic procedure (with videos). Issue 15 (April 2017)
- Main Title:
- A feasibility study of digital single-operator cholangioscopy for diagnostic and therapeutic procedure (with videos)
- Authors:
- Imanishi, Miyuki
Ogura, Takeshi
Kurisu, Yoshitaka
Onda, Saori
Takagi, Wataru
Okuda, Atsushi
Miyano, Akira
Amano, Mio
Nishioka, Nobu
Masuda, Daisuke
Higuchi, Kazuhide - Other Names:
- Žarko. Babić section editor.
- Abstract:
- Abstract : Abstract: Recently, the novel SpyGlass DS Direct Visualization system (SPY DS) has become available. This system offers several advantages over the conventional SPYGlass system. This study evaluated the clinical feasibility and efficacy of diagnostic and therapeutic procedures for biliary disorder using SPY DS. In this retrospective study, consecutive patients who had biliary disorder were enrolled between November 2015 and February 2016. All patients could not be diagnosed or treated by standard endoscopic retrograde cholangiopancreatography in our hospital or at another hospital. A total of 28 consecutive patients (21 men and 7 women; median age, 73 years; age range, 55–87 years) were retrospectively enrolled in this study. Among them, diagnostic procedure was performed in 20 patients, and 8 patients underwent therapeutic procedures. The technical success rate for diagnostic procedures was 100% (20/20). Diagnostic accuracy was 100% (19/19). The technical success rate for therapeutic procedures was 88% (7/8). Among these 8 patients, 4 patients with common bile duct stones underwent electrohydraulic lithotripsy. One patient successfully underwent guidewire insertion to remove a migrated plastic stent. The 3 remaining patients underwent SPY DS to insert a guidewire for left bile duct obstruction and for posterior bile duct branch. In the patient who underwent guidewire insertion for left hepatic bile duct obstruction cause by primary sclerosing cholangitis, weAbstract : Abstract: Recently, the novel SpyGlass DS Direct Visualization system (SPY DS) has become available. This system offers several advantages over the conventional SPYGlass system. This study evaluated the clinical feasibility and efficacy of diagnostic and therapeutic procedures for biliary disorder using SPY DS. In this retrospective study, consecutive patients who had biliary disorder were enrolled between November 2015 and February 2016. All patients could not be diagnosed or treated by standard endoscopic retrograde cholangiopancreatography in our hospital or at another hospital. A total of 28 consecutive patients (21 men and 7 women; median age, 73 years; age range, 55–87 years) were retrospectively enrolled in this study. Among them, diagnostic procedure was performed in 20 patients, and 8 patients underwent therapeutic procedures. The technical success rate for diagnostic procedures was 100% (20/20). Diagnostic accuracy was 100% (19/19). The technical success rate for therapeutic procedures was 88% (7/8). Among these 8 patients, 4 patients with common bile duct stones underwent electrohydraulic lithotripsy. One patient successfully underwent guidewire insertion to remove a migrated plastic stent. The 3 remaining patients underwent SPY DS to insert a guidewire for left bile duct obstruction and for posterior bile duct branch. In the patient who underwent guidewire insertion for left hepatic bile duct obstruction cause by primary sclerosing cholangitis, we could not advance the guidewire into the left hepatic bile duct. No adverse events were seen. Median SPY DS insertion time was 21 min (range, 8–32 min). Single-operator cholangioscopy using SPY DS was feasible and had a marked clinical impact in patients with biliary disease. Additional case reports and prospective studies are needed to examine further applications of this system. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Medicine. Volume 96:Issue 15(2017)
- Journal:
- Medicine
- Issue:
- Volume 96:Issue 15(2017)
- Issue Display:
- Volume 96, Issue 15 (2017)
- Year:
- 2017
- Volume:
- 96
- Issue:
- 15
- Issue Sort Value:
- 2017-0096-0015-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04
- Subjects:
- cholangioscope -- cholangioscopy -- endoscopic retrograde cholangiopancreatography -- peroral cholangioscopy -- SpyGlass
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000006619 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2449.xml