Fast comprehensive single‐sequence four‐dimensional pediatric knee MRI with T2 shuffling. Issue 6 (11th October 2016)
- Record Type:
- Journal Article
- Title:
- Fast comprehensive single‐sequence four‐dimensional pediatric knee MRI with T2 shuffling. Issue 6 (11th October 2016)
- Main Title:
- Fast comprehensive single‐sequence four‐dimensional pediatric knee MRI with T2 shuffling
- Authors:
- Bao, Shanshan
Tamir, Jonathan I.
Young, Jeffrey L.
Tariq, Umar
Uecker, Martin
Lai, Peng
Chen, Weitian
Lustig, Michael
Vasanawala, Shreyas S. - Abstract:
- Abstract : Purpose: To develop and clinically evaluate a pediatric knee magnetic resonance imaging (MRI) technique based on volumetric fast spin‐echo (3DFSE) and compare its diagnostic performance, image quality, and imaging time to that of a conventional 2D protocol. Materials and Methods: A 3DFSE sequence was modified and combined with a compressed sensing‐based reconstruction resolving multiple image contrasts, a technique termed T 2 Shuffling ( T 2 Sh). With Institutional Review Board (IRB) approval, 28 consecutive children referred for 3T knee MRI prospectively underwent a standard clinical knee protocol followed by T 2 Sh. T 2 Sh performance was assessed by two readers blinded to diagnostic reports. Interpretive discrepancies were resolved by medical record chart review and consensus between the readers and an orthopedic surgeon. Image quality was evaluated by rating anatomic delineation, with 95% confidence interval. A Wilcoxon rank‐sum test assessed the null hypothesis that T 2 Sh structure delineation compared to conventional 2D is unchanged. Intraclass correlation coefficients were calculated for interobserver agreement. Imaging time of the conventional protocol and T 2 Sh was compared. Results: There was 81% and 87% concordance between T 2 Sh reports and diagnostic reports, respectively, for each reader. Upon consensus review, T 2 Sh had 93% sensitivity and 100% specificity compared to clinical reports for detection of clinically relevant findings. The 95%Abstract : Purpose: To develop and clinically evaluate a pediatric knee magnetic resonance imaging (MRI) technique based on volumetric fast spin‐echo (3DFSE) and compare its diagnostic performance, image quality, and imaging time to that of a conventional 2D protocol. Materials and Methods: A 3DFSE sequence was modified and combined with a compressed sensing‐based reconstruction resolving multiple image contrasts, a technique termed T 2 Shuffling ( T 2 Sh). With Institutional Review Board (IRB) approval, 28 consecutive children referred for 3T knee MRI prospectively underwent a standard clinical knee protocol followed by T 2 Sh. T 2 Sh performance was assessed by two readers blinded to diagnostic reports. Interpretive discrepancies were resolved by medical record chart review and consensus between the readers and an orthopedic surgeon. Image quality was evaluated by rating anatomic delineation, with 95% confidence interval. A Wilcoxon rank‐sum test assessed the null hypothesis that T 2 Sh structure delineation compared to conventional 2D is unchanged. Intraclass correlation coefficients were calculated for interobserver agreement. Imaging time of the conventional protocol and T 2 Sh was compared. Results: There was 81% and 87% concordance between T 2 Sh reports and diagnostic reports, respectively, for each reader. Upon consensus review, T 2 Sh had 93% sensitivity and 100% specificity compared to clinical reports for detection of clinically relevant findings. The 95% confidence interval of diagnostic or better rating was 95–100%, with 34–80% interobserver agreement. There was no significant difference in structure delineation between T 2 Sh and 2D, except for the retinaculum ( P < 0.05), where 2D was preferred. Typical imaging time for T 2 Sh and the conventional exam was 7 and 13 minutes, respectively. Conclusion: A single‐sequence pediatric knee exam is feasible with T 2 Sh, providing multiplanar, reformattable 4D images. Level of Evidence : 2 J. MAGN. RESON. IMAGING 2017;45:1700–1711 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 45:Issue 6(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 45:Issue 6(2017)
- Issue Display:
- Volume 45, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 6
- Issue Sort Value:
- 2017-0045-0006-0000
- Page Start:
- 1700
- Page End:
- 1711
- Publication Date:
- 2016-10-11
- Subjects:
- knee MRI -- pediatric -- volumetric -- compressed sensing -- CUBE -- SPACE
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25508 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 143.xml