Amide proton transfer imaging of brain tumors using a self‐corrected 3D fast spin‐echo dixon method: Comparison With separate B0 correction. Issue 6 (6th July 2016)
- Record Type:
- Journal Article
- Title:
- Amide proton transfer imaging of brain tumors using a self‐corrected 3D fast spin‐echo dixon method: Comparison With separate B0 correction. Issue 6 (6th July 2016)
- Main Title:
- Amide proton transfer imaging of brain tumors using a self‐corrected 3D fast spin‐echo dixon method: Comparison With separate B0 correction
- Authors:
- Togao, Osamu
Keupp, Jochen
Hiwatashi, Akio
Yamashita, Koji
Kikuchi, Kazufumi
Yoneyama, Masami
Honda, Hiroshi - Abstract:
- Abstract : Purpose: To assess the quantitative performance of three‐dimensional (3D) fast spin‐echo (FSE) Dixon amide proton transfer (APT) imaging of brain tumors compared with B0 correction with separate mapping methods. Methods: Twenty‐two patients with brain tumors (54.2 ± 18.7 years old, 12 males and 10 females) were scanned at 3 Tesla (T). Z‐spectra were obtained at seven different frequency offsets at ±3.1 ppm, ± 3.5 ppm, ± 3.9 ppm, and −1560 ppm. The scan was repeated three times at +3.5 ppm with echo shifts for Dixon B0 mapping. The APT image corrected by a three‐point Dixon‐type B0 map from the same scan (3D‐Dixon) or a separate B0 map (2D‐separate and 3D‐separate), and an uncorrected APT image (3D‐uncorrected) were generated. We compared the APT‐weighted signals within a tumor obtained with each 3D method with those obtained with 2D‐separate as a reference standard. Results: Excellent agreements and correlations with the 2D‐separate were obtained by the 3D‐Dixon method for both mean (ICC = 0.964, r = 0.93, P < 0.0001) and 90th‐percentile (ICC = 0.972, r = 0.95, P < 0.0001) APT‐weighted signals. These agreements and correlations for 3D‐Dixon were better than those obtained by the 3D‐uncorrected and 3D‐separate methods. Conclusion: The 3D FSE Dixon APT method with intrinsic B0 correction offers a quantitative performance that is similar to that of established two‐dimensional (2D) methods. Magn Reson Med 77:2272–2279, 2017. © 2016 International Society forAbstract : Purpose: To assess the quantitative performance of three‐dimensional (3D) fast spin‐echo (FSE) Dixon amide proton transfer (APT) imaging of brain tumors compared with B0 correction with separate mapping methods. Methods: Twenty‐two patients with brain tumors (54.2 ± 18.7 years old, 12 males and 10 females) were scanned at 3 Tesla (T). Z‐spectra were obtained at seven different frequency offsets at ±3.1 ppm, ± 3.5 ppm, ± 3.9 ppm, and −1560 ppm. The scan was repeated three times at +3.5 ppm with echo shifts for Dixon B0 mapping. The APT image corrected by a three‐point Dixon‐type B0 map from the same scan (3D‐Dixon) or a separate B0 map (2D‐separate and 3D‐separate), and an uncorrected APT image (3D‐uncorrected) were generated. We compared the APT‐weighted signals within a tumor obtained with each 3D method with those obtained with 2D‐separate as a reference standard. Results: Excellent agreements and correlations with the 2D‐separate were obtained by the 3D‐Dixon method for both mean (ICC = 0.964, r = 0.93, P < 0.0001) and 90th‐percentile (ICC = 0.972, r = 0.95, P < 0.0001) APT‐weighted signals. These agreements and correlations for 3D‐Dixon were better than those obtained by the 3D‐uncorrected and 3D‐separate methods. Conclusion: The 3D FSE Dixon APT method with intrinsic B0 correction offers a quantitative performance that is similar to that of established two‐dimensional (2D) methods. Magn Reson Med 77:2272–2279, 2017. © 2016 International Society for Magnetic Resonance in Medicine … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 77:Issue 6(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 77:Issue 6(2017)
- Issue Display:
- Volume 77, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 6
- Issue Sort Value:
- 2017-0077-0006-0000
- Page Start:
- 2272
- Page End:
- 2279
- Publication Date:
- 2016-07-06
- Subjects:
- amide proton transfer (APT) imaging -- chemical exchange saturation transfer (CEST) -- Dixon -- brain tumor
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26322 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2102.xml