Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI. Issue 6 (8th September 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI. Issue 6 (8th September 2016)
- Main Title:
- Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI
- Authors:
- Kallehauge, Jesper F.
Sourbron, Steven
Irving, Benjamin
Tanderup, Kari
Schnabel, Julia A.
Chappell, Michael A. - Abstract:
- Abstract : Purpose: Fitting tracer kinetic models using linear methods is much faster than using their nonlinear counterparts, although this comes often at the expense of reduced accuracy and precision. The aim of this study was to derive and compare the performance of the linear compartmental tissue uptake (CTU) model with its nonlinear version with respect to their percentage error and precision. Theory and Methods: The linear and nonlinear CTU models were initially compared using simulations with varying noise and temporal sampling. Subsequently, the clinical applicability of the linear model was demonstrated on 14 patients with locally advanced cervical cancer examined with dynamic contrast‐enhanced magnetic resonance imaging. Results: Simulations revealed equal percentage error and precision when noise was within clinical achievable ranges (contrast‐to‐noise ratio >10). The linear method was significantly faster than the nonlinear method, with a minimum speedup of around 230 across all tested sampling rates. Clinical analysis revealed that parameters estimated using the linear and nonlinear CTU model were highly correlated (ρ ≥ 0.95). Conclusion: The linear CTU model is computationally more efficient and more stable against temporal downsampling, whereas the nonlinear method is more robust to variations in noise. The two methods may be used interchangeably within clinical achievable ranges of temporal sampling and noise. Magn Reson Med 77:2414–2423, 2017. © 2016 TheAbstract : Purpose: Fitting tracer kinetic models using linear methods is much faster than using their nonlinear counterparts, although this comes often at the expense of reduced accuracy and precision. The aim of this study was to derive and compare the performance of the linear compartmental tissue uptake (CTU) model with its nonlinear version with respect to their percentage error and precision. Theory and Methods: The linear and nonlinear CTU models were initially compared using simulations with varying noise and temporal sampling. Subsequently, the clinical applicability of the linear model was demonstrated on 14 patients with locally advanced cervical cancer examined with dynamic contrast‐enhanced magnetic resonance imaging. Results: Simulations revealed equal percentage error and precision when noise was within clinical achievable ranges (contrast‐to‐noise ratio >10). The linear method was significantly faster than the nonlinear method, with a minimum speedup of around 230 across all tested sampling rates. Clinical analysis revealed that parameters estimated using the linear and nonlinear CTU model were highly correlated (ρ ≥ 0.95). Conclusion: The linear CTU model is computationally more efficient and more stable against temporal downsampling, whereas the nonlinear method is more robust to variations in noise. The two methods may be used interchangeably within clinical achievable ranges of temporal sampling and noise. Magn Reson Med 77:2414–2423, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of theCreative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 77:Issue 6(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 77:Issue 6(2017)
- Issue Display:
- Volume 77, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 6
- Issue Sort Value:
- 2017-0077-0006-0000
- Page Start:
- 2414
- Page End:
- 2423
- Publication Date:
- 2016-09-08
- Subjects:
- DCE‐MRI -- tracer kinetic modeling -- pharmacokinetics -- cervical cancer -- linear least‐squares method -- nonlinear least‐squares
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26324 ↗
- Languages:
- English