Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta‐analysis. Issue 5 (8th April 2016)
- Record Type:
- Journal Article
- Title:
- Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta‐analysis. Issue 5 (8th April 2016)
- Main Title:
- Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta‐analysis
- Authors:
- Raico Gallardo, Yolanda Natali
da Silva‐Olivio, Isabela Rodrigues Teixeira
Mukai, Eduardo
Morimoto, Susana
Sesma, Newton
Cordaro, Luca - Abstract:
- Abstract: Aim: To systematically assess the current dental literature comparing the accuracy of computer‐aided implant surgery when using different supporting tissues (tooth, mucosa, or bone). Material and Methods: Two reviewers searched PubMed (1972 to January 2015) and the Cochrane Central Register of Controlled Trials (Central) (2002 to January 2015). For the assessment of accuracy, studies were included with the following outcome measures: (i) angle deviation, (ii) deviation at the entry point, and (iii) deviation at the apex. Results: Eight clinical studies from the 1602 articles initially identified met the inclusion criteria for the qualitative analysis. Four studies ( n = 599 implants) were evaluated using meta‐analysis. The bone‐supported guides showed a statistically significant greater deviation in angle ( P < 0.001), entry point ( P = 0.01), and the apex ( P = 0.001) when compared to the tooth‐supported guides. Conversely, when only retrospective studies were analyzed, not significant differences are revealed in the deviation of the entry point and apex. The mucosa‐supported guides indicated a statistically significant greater reduction in angle deviation ( P = 0.02), deviation at the entry point ( P = 0.002), and deviation at the apex ( P = 0.04) when compared to the bone‐supported guides. Between the mucosa‐ and tooth‐supported guides, there were no statistically significant differences for any of the outcome measures. Conclusions: It can be concludedAbstract: Aim: To systematically assess the current dental literature comparing the accuracy of computer‐aided implant surgery when using different supporting tissues (tooth, mucosa, or bone). Material and Methods: Two reviewers searched PubMed (1972 to January 2015) and the Cochrane Central Register of Controlled Trials (Central) (2002 to January 2015). For the assessment of accuracy, studies were included with the following outcome measures: (i) angle deviation, (ii) deviation at the entry point, and (iii) deviation at the apex. Results: Eight clinical studies from the 1602 articles initially identified met the inclusion criteria for the qualitative analysis. Four studies ( n = 599 implants) were evaluated using meta‐analysis. The bone‐supported guides showed a statistically significant greater deviation in angle ( P < 0.001), entry point ( P = 0.01), and the apex ( P = 0.001) when compared to the tooth‐supported guides. Conversely, when only retrospective studies were analyzed, not significant differences are revealed in the deviation of the entry point and apex. The mucosa‐supported guides indicated a statistically significant greater reduction in angle deviation ( P = 0.02), deviation at the entry point ( P = 0.002), and deviation at the apex ( P = 0.04) when compared to the bone‐supported guides. Between the mucosa‐ and tooth‐supported guides, there were no statistically significant differences for any of the outcome measures. Conclusions: It can be concluded that the tissue of the guide support influences the accuracy of computer‐aided implant surgery. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 28:Issue 5(2017)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 28:Issue 5(2017)
- Issue Display:
- Volume 28, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 28
- Issue:
- 5
- Issue Sort Value:
- 2017-0028-0005-0000
- Page Start:
- 602
- Page End:
- 612
- Publication Date:
- 2016-04-08
- Subjects:
- computer‐aided design -- computer‐aided manufacturing -- computer‐aided surgery -- dental implants -- systematic review
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12841 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1150.xml