An inflatable ergonomic 3‐chamber fundal pressure belt to assist vaginal delivery. Issue 1 (16th October 2012)
- Record Type:
- Journal Article
- Title:
- An inflatable ergonomic 3‐chamber fundal pressure belt to assist vaginal delivery. Issue 1 (16th October 2012)
- Main Title:
- An inflatable ergonomic 3‐chamber fundal pressure belt to assist vaginal delivery
- Authors:
- Acanfora, Luisa
Rampon, Michela
Filippeschi, Marco
Marchi, Marco
Montisci, Massimo
Viel, Guido
Cosmi, Erich - Abstract:
- Abstract: Objective: To evaluate whether Baby‐guard—a new medical device with an ergonomic 3‐chamber inflatable abdominal belt—can reduce complications associated with vaginal delivery. Methods: A randomized controlled single‐blind prospective study of 80 pregnant women delivering at term was conducted at San Giuseppe Hospital, Empoli, Italy. In the study group (n = 40), the abdominal belt was inflated to optimal therapeutic pressures. In the control group (n = 40), the abdominal belt was inflated to minimal, non‐therapeutic pressures. Factors relating to maternal, fetal, and labor complications during vaginal delivery were evaluated. Results: Compared with the control group, women in the study group experienced a lower incidence of perineal and cervical lacerations ( P < 0.001); reduced use of the Kristeller maneuver ( P < 0.001); shorter duration of the second stage of labor ( P < 0.001); less psychologic and physical fatigue ( P < 0.001); fewer maternal requests for cesarean delivery during labor ( P < 0.001); fewer vacuum extractions ( P < 0.01); and fewer cesarean deliveries ( P < 0.02). No neonatal intensive care unit admissions were recorded in the study group versus 7 in the control group ( P < 0.012). Conclusion: Use of the ergonomic 3‐chamber inflatable abdominal belt system reduced the incidence of risks associated with vaginal labor. Clinicaltrials.gov identifier: NCT01566331.
- Is Part Of:
- International journal of gynaecology and obstetrics. Volume 120:Issue 1(2013)
- Journal:
- International journal of gynaecology and obstetrics
- Issue:
- Volume 120:Issue 1(2013)
- Issue Display:
- Volume 120, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 120
- Issue:
- 1
- Issue Sort Value:
- 2013-0120-0001-0000
- Page Start:
- 78
- Page End:
- 81
- Publication Date:
- 2012-10-16
- Subjects:
- Complication -- Labor -- Outcome -- Safety -- Uterine fundal pressure -- Vaginal delivery
Gynecology -- Periodicals
Obstetrics -- Periodicals
Electronic journals
618 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00207292 ↗
http://www.sciencedirect.com/science/journal/00207292 ↗
https://obgyn.onlinelibrary.wiley.com/journal/18793479 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijgo.2012.07.025 ↗
- Languages:
- English
- ISSNs:
- 0020-7292
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.273000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1076.xml