Laryngeal view and temperature measurements while using the perilaryngeal airway (Cobra‐PLUS™) in children. Issue 12 (25th September 2013)
- Record Type:
- Journal Article
- Title:
- Laryngeal view and temperature measurements while using the perilaryngeal airway (Cobra‐PLUS™) in children. Issue 12 (25th September 2013)
- Main Title:
- Laryngeal view and temperature measurements while using the perilaryngeal airway (Cobra‐PLUS™) in children
- Authors:
- Tan, Gee Mei
Galinkin, Jeffrey L.
Pan, Zhaoxing
Polaner, David M. - Editors:
- Cote, Charles
- Abstract:
- Summary: Introduction: The Cobra‐PLUS™ perilaryngeal airway (CP) is a modification of the Cobra perilaryngeal airway. It has a distal curve for easier placement and a thermistor on the pharyngeal cuff. We assessed the orientation of the larynx to the CP and compared temperatures measured using CP to temporal arterial (TA) and infrared tympanic (T) thermometers. Methodology: American Society of Anesthesiologists (ASA) physical status 1 and 2 children 0–18 years old undergoing general anesthesia using CP were grouped into different weight cohorts. A fiberoptic scope was inserted through the CP, and laryngeal views were recorded and graded off line. Temperatures were measured from the CP, TA, and T at 15‐min intervals for four readings or until the end of surgery. The CP was removed, while the patient was deeply anesthetized. Results: Eighty subjects were analyzed. 87.5% (cohort range 75–95%) had an unobstructed view of the larynx. No serious adverse effects noted. Three hundred and sixteen temperature data points were recorded for each measured site. CP temperatures were consistently lower than TA and T with a bias of 0.9 and 0.6°C, respectively. Using temperatures measured at time 0 and 15 min, CP was associated with a larger intraclass correlation coefficient and smaller repeatability coefficient when compared to TA or T (ICC 0.65, 0.46. 0.44 and RC 0.78, 1, 1.36, respectively), indicating it had a better measure and remeasure reliability. Conclusion: The CP has a betterSummary: Introduction: The Cobra‐PLUS™ perilaryngeal airway (CP) is a modification of the Cobra perilaryngeal airway. It has a distal curve for easier placement and a thermistor on the pharyngeal cuff. We assessed the orientation of the larynx to the CP and compared temperatures measured using CP to temporal arterial (TA) and infrared tympanic (T) thermometers. Methodology: American Society of Anesthesiologists (ASA) physical status 1 and 2 children 0–18 years old undergoing general anesthesia using CP were grouped into different weight cohorts. A fiberoptic scope was inserted through the CP, and laryngeal views were recorded and graded off line. Temperatures were measured from the CP, TA, and T at 15‐min intervals for four readings or until the end of surgery. The CP was removed, while the patient was deeply anesthetized. Results: Eighty subjects were analyzed. 87.5% (cohort range 75–95%) had an unobstructed view of the larynx. No serious adverse effects noted. Three hundred and sixteen temperature data points were recorded for each measured site. CP temperatures were consistently lower than TA and T with a bias of 0.9 and 0.6°C, respectively. Using temperatures measured at time 0 and 15 min, CP was associated with a larger intraclass correlation coefficient and smaller repeatability coefficient when compared to TA or T (ICC 0.65, 0.46. 0.44 and RC 0.78, 1, 1.36, respectively), indicating it had a better measure and remeasure reliability. Conclusion: The CP has a better orientation to the larynx compared with its previous version. It may be used to reliably trend intraoperative temperatures. … (more)
- Is Part Of:
- Paediatric anaesthesia. Volume 23:Issue 12(2013)
- Journal:
- Paediatric anaesthesia
- Issue:
- Volume 23:Issue 12(2013)
- Issue Display:
- Volume 23, Issue 12 (2013)
- Year:
- 2013
- Volume:
- 23
- Issue:
- 12
- Issue Sort Value:
- 2013-0023-0012-0000
- Page Start:
- 1180
- Page End:
- 1186
- Publication Date:
- 2013-09-25
- Subjects:
- airway management -- supraglottic airway devices -- intraoperative monitoring -- body temperature -- children -- infants
Pediatric anesthesia -- Periodicals
617.96798 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1155-5645&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1460-9592 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/pan.12266 ↗
- Languages:
- English
- ISSNs:
- 1155-5645
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6333.399705
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1790.xml