Accuracy of acoustic respiration rate monitoring in pediatric patients. Issue 12 (3rd September 2013)
- Record Type:
- Journal Article
- Title:
- Accuracy of acoustic respiration rate monitoring in pediatric patients. Issue 12 (3rd September 2013)
- Main Title:
- Accuracy of acoustic respiration rate monitoring in pediatric patients
- Authors:
- Patino, Mario
Redford, Daniel T.
Quigley, Thomas W.
Mahmoud, Mohamed
Kurth, C. Dean
Szmuk, Peter - Editors:
- Lerman, Jerrold
- Abstract:
- Summary: Background: Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. Objective: We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. Methods: Continuous respiration rate data were recorded from RRa and capnography. In a subset of patients, intermittent respiration rate from thoracic impedance pneumography was also recorded. The reference method, counted respiratory rate by the retrospective analysis of the RRa, and capnographic waveforms while listening to recorded breath sounds were used to compare respiration rate of both capnography and RRa. Bias, precision, and limits of agreement of RRa compared with capnography and RRa and capnography compared with the reference method were calculated. Tolerance and reliability to the acoustic sensor and nasal cannula were also assessed. Results: Thirty‐nine of 40 patients (97.5%) demonstrated good tolerance of the acoustic sensor, whereas 25 of 40 patients (62.5%) demonstrated good tolerance of the nasal cannula. Intermittent thoracic impedance produced erroneous respiratory rates (>50 b·min −1 from the other methods) on 47% of occasions. The bias ± SD and limits of agreement were −0.30 ± 3.5 b·min −1 and −7.3 to 6.6 b·min −1 for RRa compared with capnography; −0.1 ± 2.5 b·min −1 and −5.0 toSummary: Background: Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. Objective: We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. Methods: Continuous respiration rate data were recorded from RRa and capnography. In a subset of patients, intermittent respiration rate from thoracic impedance pneumography was also recorded. The reference method, counted respiratory rate by the retrospective analysis of the RRa, and capnographic waveforms while listening to recorded breath sounds were used to compare respiration rate of both capnography and RRa. Bias, precision, and limits of agreement of RRa compared with capnography and RRa and capnography compared with the reference method were calculated. Tolerance and reliability to the acoustic sensor and nasal cannula were also assessed. Results: Thirty‐nine of 40 patients (97.5%) demonstrated good tolerance of the acoustic sensor, whereas 25 of 40 patients (62.5%) demonstrated good tolerance of the nasal cannula. Intermittent thoracic impedance produced erroneous respiratory rates (>50 b·min −1 from the other methods) on 47% of occasions. The bias ± SD and limits of agreement were −0.30 ± 3.5 b·min −1 and −7.3 to 6.6 b·min −1 for RRa compared with capnography; −0.1 ± 2.5 b·min −1 and −5.0 to 5.0 b·min −1 for RRa compared with the reference method; and 0.2 ± 3.4 b·min −1 and −6.8 to 6.7 b·min −1 for capnography compared with the reference method. Conclusions: When compared to nasal capnography, RRa showed good agreement and similar accuracy and precision but was better tolerated in postsurgical pediatric patients. … (more)
- Is Part Of:
- Paediatric anaesthesia. Volume 23:Issue 12(2013)
- Journal:
- Paediatric anaesthesia
- Issue:
- Volume 23:Issue 12(2013)
- Issue Display:
- Volume 23, Issue 12 (2013)
- Year:
- 2013
- Volume:
- 23
- Issue:
- 12
- Issue Sort Value:
- 2013-0023-0012-0000
- Page Start:
- 1166
- Page End:
- 1173
- Publication Date:
- 2013-09-03
- Subjects:
- MeSH -- apnea -- capnography -- monitoring physiologic -- oximetry -- postanesthesia nursing -- respiration rate
Pediatric anesthesia -- Periodicals
617.96798 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1155-5645&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1460-9592 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/pan.12254 ↗
- Languages:
- English
- ISSNs:
- 1155-5645
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6333.399705
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1790.xml