Lippi, G. - Abstract:
- Abstract: Introduction: The enumeration and differentiation of nuclear elements in synovial fluid is a cornerstone for diagnosis and follow‐up of many orthopedic and rheumatologic diseases. In this study, we evaluated the analytical performance of Mindray BC‐6800 BF mode (BC‐6800‐BF) for synovial fluid analysis. Methods: Overall, 78 synovial fluids were collected and analyzed with both BC‐6800‐BF and light microscopy. The study also entailed the assessment of limit of blank (LoB), limit of detection (LoD), limit of quantification (LoQ), carryover and linearity. Results: The LoB for the parameters total cells and white blood cells was 6 × 10 6 cells/L, and the LoD and LoQ were instead 15 and 16 × 10 6 cells/L, respectively. Linearity was excellent and carryover was negligible. The agreement between BC‐6800‐BF and light microscopy was satisfactory for all samples pretreated with hyaluronidase, displaying a bias between −5.9% and 8.2%. Conclusions: The use of BC‐6800‐BF for synovial fluid analysis enables rapid and accurate assessment, especially for total cell and polymorphonuclear counts. The use of BC‐6800‐BF may therefore allow the replacement of optical analysis, especially in samples pretreated with hyaluronidase, thus allowing its routine use for the screening of synovial specimens.
- Is Part Of:
- International journal of laboratory hematology. Volume 39:Number 3(2017:Jun.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 39:Number 3(2017:Jun.)
- Issue Display:
- Volume 39, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 39
- Issue:
- 3
- Issue Sort Value:
- 2017-0039-0003-0000
- Page Start:
- 337
- Page End:
- 346
- Publication Date:
- 2017-03-06
- Subjects:
- Synovial fluid -- light microscopy -- Mindray -- BC‐6800 -- body fluid
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12632 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2606.xml