An ionic liquid doped electrochemical copolymer coating of indole and 3-methylthiophene for the solid-phase microextraction of polycyclic aromatic hydrocarbons. Issue 36 (21st April 2017)
- Record Type:
- Journal Article
- Title:
- An ionic liquid doped electrochemical copolymer coating of indole and 3-methylthiophene for the solid-phase microextraction of polycyclic aromatic hydrocarbons. Issue 36 (21st April 2017)
- Main Title:
- An ionic liquid doped electrochemical copolymer coating of indole and 3-methylthiophene for the solid-phase microextraction of polycyclic aromatic hydrocarbons
- Authors:
- Guo, Xiafei
mulati, Aiziguli
Wu, Mian
Zhang, Jie
Yang, Liu
Zhao, Faqiong
Zeng, Baizhao - Abstract:
- Abstract : Poly(indole- co -3-methylthiophene)-ionic liquid (P(In–3-MeT)/IL) composite film was electrodeposited on a stainless steel wire for SPME. Abstract : A novel poly(indole- co -3-methylthiophene)–ionic liquid ( i.e., 1-allyl-3-vinylimidazolium bis((trifluoromethyl)sulfonyl)imide) (P(In–3-MeT)/IL) composite film was electrodeposited on a stainless steel wire for headspace solid phase microextraction. The obtained P(In–3-MeT)/IL coating was rough and showed a cauliflower-shape. It had high thermal stability (up to 450 °C) and mechanical stability and could be used for at least 180 times in solid phase microextraction (SPME) without a decrease in extraction performance. The coating exhibited high extraction capacity for some polycyclic aromatic hydrocarbons ( e.g. naphthalene, 1-methylnaphthalene, acenaphthene, biphenyl, fluorene and phenanthrene) due to the strong hydrophobic and π–π interactions between the analytes and P(In–3-MeT)/IL. Through coupling with GC, good linearity (correlation coefficients higher than 0.9994), wide linear ranges (0.05–50 μg L −1 ) and low limits of detection (6.25–25.2 ng L −1 ) were achieved for these analytes. The reproducibility (defined as RSD) was 3.5–5.5% and 4.5–7.2% for single fiber ( n = 5) and fiber-to-fiber ( n = 5), respectively. The SPME-GC method was successfully applied for the determination of three real samples, and the recoveries for standards added were 86.8–105% for mosquito-repellent incense, 89.9–110% for cigarettesAbstract : Poly(indole- co -3-methylthiophene)-ionic liquid (P(In–3-MeT)/IL) composite film was electrodeposited on a stainless steel wire for SPME. Abstract : A novel poly(indole- co -3-methylthiophene)–ionic liquid ( i.e., 1-allyl-3-vinylimidazolium bis((trifluoromethyl)sulfonyl)imide) (P(In–3-MeT)/IL) composite film was electrodeposited on a stainless steel wire for headspace solid phase microextraction. The obtained P(In–3-MeT)/IL coating was rough and showed a cauliflower-shape. It had high thermal stability (up to 450 °C) and mechanical stability and could be used for at least 180 times in solid phase microextraction (SPME) without a decrease in extraction performance. The coating exhibited high extraction capacity for some polycyclic aromatic hydrocarbons ( e.g. naphthalene, 1-methylnaphthalene, acenaphthene, biphenyl, fluorene and phenanthrene) due to the strong hydrophobic and π–π interactions between the analytes and P(In–3-MeT)/IL. Through coupling with GC, good linearity (correlation coefficients higher than 0.9994), wide linear ranges (0.05–50 μg L −1 ) and low limits of detection (6.25–25.2 ng L −1 ) were achieved for these analytes. The reproducibility (defined as RSD) was 3.5–5.5% and 4.5–7.2% for single fiber ( n = 5) and fiber-to-fiber ( n = 5), respectively. The SPME-GC method was successfully applied for the determination of three real samples, and the recoveries for standards added were 86.8–105% for mosquito-repellent incense, 89.9–110% for cigarettes and 82.3–103% for industrial lubricant. … (more)
- Is Part Of:
- RSC advances. Volume 7:Issue 36(2017)
- Journal:
- RSC advances
- Issue:
- Volume 7:Issue 36(2017)
- Issue Display:
- Volume 7, Issue 36 (2017)
- Year:
- 2017
- Volume:
- 7
- Issue:
- 36
- Issue Sort Value:
- 2017-0007-0036-0000
- Page Start:
- 22256
- Page End:
- 22262
- Publication Date:
- 2017-04-21
- Subjects:
- Chemistry -- Periodicals
540.5 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/RA ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7ra02372c ↗
- Languages:
- English
- ISSNs:
- 2046-2069
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8036.750300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: