A comparative study of various methods for detection of IL28B rs12979860 in chronic hepatitis C. (19th May 2017)
- Record Type:
- Journal Article
- Title:
- A comparative study of various methods for detection of IL28B rs12979860 in chronic hepatitis C. (19th May 2017)
- Main Title:
- A comparative study of various methods for detection of IL28B rs12979860 in chronic hepatitis C
- Authors:
- Monavari, Seyed Hamidreza
Fateh, Roohollah
Vaziri, Farzam
Rahimi Jamnani, Fatemeh
Anvari, Enayat
Sadeghi, Farzin
Afrough, Parviz
Behrouzi, Ava
Sakhaee, Fatemeh
Meidaninikjeh, Sepideh
Mollaie, Hamidreza
Hadizadeh Tasbiti, Alireza
Yari, Shamsi
Sadeghi, Maryam
Fateh, Abolfazl
Siadat, Seyed Davar - Abstract:
- Abstract: Interleukin-28B ( IL28B ) single-nucleotide polymorphisms (SNPs) constitute important host-related factors influencing the response rate to Hepatitis C virus (HCV) standard antiviral therapy. In the last few years, several new technologies for SNP detection have been developed. However, the sensitivity and specificity of various methods are different and needs evaluation. Five different methods (resolution melting curve [RMC], polymerase chain reaction-restriction fragment length polymorphism [PCR-RFLP], PCR-sequencing analysis, amplification refractory mutation system [ARMS], and zip nucleic acid probe-based real-time PCR [ZNA]) were developed for genotyping rs12979860 associated with IL28B . In this study, limit of detection (LD), costs and turnaround time of these methods were compared in 350 subjects. As for IL28B rs12979860 polymorphisms, 348/350 (99.4%) samples were consistent among the five methods, while results for 2/350 (0.57%) samples were concordant by ZNAs and PCR-sequencing, and discordant by other methods. Without considering the cost of DNA extraction, the price of each reaction for ARMS-PCR, RMC, PCR-RFLP, ZNA and PCR-sequencing were respectively: US$3.10, US$5.0, US$5.50, US$8.50 and US$17.0. RMC was the fastest method, while the ZNA method was easy to use, reliable and effective. Lower LD was determined to be 50–60 copies/μL for the PCR-RFLP, RMC and ARMS-PCR assays; whilst ZNA assay was able to detect 2–3 copies/μL. In conclusion, in the currentAbstract: Interleukin-28B ( IL28B ) single-nucleotide polymorphisms (SNPs) constitute important host-related factors influencing the response rate to Hepatitis C virus (HCV) standard antiviral therapy. In the last few years, several new technologies for SNP detection have been developed. However, the sensitivity and specificity of various methods are different and needs evaluation. Five different methods (resolution melting curve [RMC], polymerase chain reaction-restriction fragment length polymorphism [PCR-RFLP], PCR-sequencing analysis, amplification refractory mutation system [ARMS], and zip nucleic acid probe-based real-time PCR [ZNA]) were developed for genotyping rs12979860 associated with IL28B . In this study, limit of detection (LD), costs and turnaround time of these methods were compared in 350 subjects. As for IL28B rs12979860 polymorphisms, 348/350 (99.4%) samples were consistent among the five methods, while results for 2/350 (0.57%) samples were concordant by ZNAs and PCR-sequencing, and discordant by other methods. Without considering the cost of DNA extraction, the price of each reaction for ARMS-PCR, RMC, PCR-RFLP, ZNA and PCR-sequencing were respectively: US$3.10, US$5.0, US$5.50, US$8.50 and US$17.0. RMC was the fastest method, while the ZNA method was easy to use, reliable and effective. Lower LD was determined to be 50–60 copies/μL for the PCR-RFLP, RMC and ARMS-PCR assays; whilst ZNA assay was able to detect 2–3 copies/μL. In conclusion, in the current study, all four methods are suitable for IL28B rs12979860 genotyping, but the ZNA assay can be a reliable tool. Due to its lower LD for SNP identification, this method is better than others for detecting this type of polymorphism. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 77:Number 4(2017)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 77:Number 4(2017)
- Issue Display:
- Volume 77, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 4
- Issue Sort Value:
- 2017-0077-0004-0000
- Page Start:
- 247
- Page End:
- 252
- Publication Date:
- 2017-05-19
- Subjects:
- Amplification refractory mutation system -- IL28B rs12979860 -- resolution melting curve -- restriction fragment length polymorphism -- zip nucleic acid real-time PCR
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2017.1299207 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2369.xml