Adhesion contact deformation in nanobridge tests. Issue 18 (26th April 2017)
- Record Type:
- Journal Article
- Title:
- Adhesion contact deformation in nanobridge tests. Issue 18 (26th April 2017)
- Main Title:
- Adhesion contact deformation in nanobridge tests
- Authors:
- Gao, Yao
Shi, San-Qiang
Zhang, Tong-Yi - Abstract:
- Abstract : The present work systematically investigates the influence of adhesion contact deformation in nanobridge tests and provides an analytical method to evaluate the contact deformation and to determine the Young's modulus. Abstract : An accurate grasp of the mechanical properties, especially Young's moduli, of one dimensional nanomaterials plays a crucial role in the design and safe service of flexible electronic devices and implanted biomedical sensors. Nanobridge tests are widely used in the characterization of the mechanical properties of nanowires. In these tests, an atomic force microscope (AFM), functioning as a test machine, exerts a force to bend a nanowire suspended across a trench or a hole with the two ends fixed on a template or substrate. Adhesion contact deformation occurs inevitably during nanobridge testing between the AFM tip and the tested sample, thereby underestimating the Young's modulus of the tested nanowire and causing a pseudo-size effect in the determined Young's modulus. The present work systematically investigates the adhesion contact deformation in nanobridge tests and provides an analytical approach to evaluate the contact deformation and to determine the Young's modulus. To illustrate the developed methodology, AFM nanobridge tests were conducted on gold nanowires (180–340 nm wide, 3.6–5.1 μm long and 90 nm thick). The results indicate that when the contact deformation was taken into consideration, the average Young's modulus increasedAbstract : The present work systematically investigates the influence of adhesion contact deformation in nanobridge tests and provides an analytical method to evaluate the contact deformation and to determine the Young's modulus. Abstract : An accurate grasp of the mechanical properties, especially Young's moduli, of one dimensional nanomaterials plays a crucial role in the design and safe service of flexible electronic devices and implanted biomedical sensors. Nanobridge tests are widely used in the characterization of the mechanical properties of nanowires. In these tests, an atomic force microscope (AFM), functioning as a test machine, exerts a force to bend a nanowire suspended across a trench or a hole with the two ends fixed on a template or substrate. Adhesion contact deformation occurs inevitably during nanobridge testing between the AFM tip and the tested sample, thereby underestimating the Young's modulus of the tested nanowire and causing a pseudo-size effect in the determined Young's modulus. The present work systematically investigates the adhesion contact deformation in nanobridge tests and provides an analytical approach to evaluate the contact deformation and to determine the Young's modulus. To illustrate the developed methodology, AFM nanobridge tests were conducted on gold nanowires (180–340 nm wide, 3.6–5.1 μm long and 90 nm thick). The results indicate that when the contact deformation was taken into consideration, the average Young's modulus increased by 4.63%. Guidelines for minimizing the impact of contact deformation in practical experiments are presented. Furthermore, the results provide insight into the probable causes of the variation in experimentally obtained size-dependencies of Young's moduli of nanowires. … (more)
- Is Part Of:
- Nanoscale. Volume 9:Issue 18(2017)
- Journal:
- Nanoscale
- Issue:
- Volume 9:Issue 18(2017)
- Issue Display:
- Volume 9, Issue 18 (2017)
- Year:
- 2017
- Volume:
- 9
- Issue:
- 18
- Issue Sort Value:
- 2017-0009-0018-0000
- Page Start:
- 6033
- Page End:
- 6040
- Publication Date:
- 2017-04-26
- Subjects:
- Nanoscience -- Periodicals
Nanotechnology -- Periodicals
620.505 - Journal URLs:
- http://www.rsc.org/Publishing/Journals/NR/Index.asp ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7nr01038a ↗
- Languages:
- English
- ISSNs:
- 2040-3364
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9830.266000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1495.xml