Balloon catheters with integrated stretchable electronics for electrical stimulation, ablation and blood flow monitoring. (June 2015)
- Record Type:
- Journal Article
- Title:
- Balloon catheters with integrated stretchable electronics for electrical stimulation, ablation and blood flow monitoring. (June 2015)
- Main Title:
- Balloon catheters with integrated stretchable electronics for electrical stimulation, ablation and blood flow monitoring
- Authors:
- Klinker, Lauren
Lee, Stephen
Work, John
Wright, John
Ma, Yinji
Ptaszek, Leon
Webb, Richard C.
Liu, Cliff
Sheth, Nirav
Mansour, Moussa
Rogers, John A.
Huang, Yonggang
Chen, Hang
Ghaffari, Roozbeh - Abstract:
- Abstract: Balloon catheter-based techniques that apply mechanical force to blood vessel walls have dramatically advanced the standard of care for patients with vascular disease. But balloons are limited in their therapeutic potential because they rely on mechanics alone and lack electronically active materials. Recent advances in balloon catheters with integrated electrodes have offered additional treatment capabilities through the application of both mechanical contact force and radio frequency electromotive force. However, these smart balloons remain limited in their mechanics and their ability to provide diagnostic information about local vessel hemodynamics and tissue health near treatment zones. Here, we demonstrate a novel instrumented balloon catheter system that contains stretchable electrodes and thermal-based blood flow sensors, providing hemodynamic information, electrical stimulation, and ablation therapy on a single device. This system accommodates high inflation pressure (∼2 atm) and twisting and bending over a broad range of vascular diameters and geometries. Finite element and analytical modeling capture the anisotropic mechanical and thermal properties of the device during cycles of inflation and deflation in a simulated biological environment. Bench-top ablation and in vivo blood flow measurements highlight the utility of this technology for clinical application.
- Is Part Of:
- Extreme mechanics letters. Volume 3(2015)
- Journal:
- Extreme mechanics letters
- Issue:
- Volume 3(2015)
- Issue Display:
- Volume 3, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 3
- Issue:
- 2015
- Issue Sort Value:
- 2015-0003-2015-0000
- Page Start:
- 45
- Page End:
- 54
- Publication Date:
- 2015-06
- Subjects:
- Stretchable electronics -- Balloon catheters -- Ablation -- Angioplasty -- Hemodynamics -- Mechanics
Mechanics -- Periodicals
Mechanics, Applied -- Periodicals
Mechanics
Electronic journals
Periodicals
531.05 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23524316 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.eml.2015.02.005 ↗
- Languages:
- English
- ISSNs:
- 2352-4316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 814.xml