Comparison of liver volumetry on contrast‐enhanced CT images: one semiautomatic and two automatic approaches. (8th November 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of liver volumetry on contrast‐enhanced CT images: one semiautomatic and two automatic approaches. (8th November 2016)
- Main Title:
- Comparison of liver volumetry on contrast‐enhanced CT images: one semiautomatic and two automatic approaches
- Authors:
- Cai, Wei
He, Baochun
Fan, Yingfang
Fang, Chihua
Jia, Fucang - Abstract:
- Abstract : This study was to evaluate the accuracy, consistency, and efficiency of three liver volumetry methods— one interactive method, an in‐house‐developed 3D medical Image Analysis (3DMIA) system, one automatic active shape model (ASM)‐based segmentation, and one automatic probabilistic atlas (PA)‐guided segmentation method on clinical contrast‐enhanced CT images. Forty‐two datasets, including 27 normal liver and 15 space‐occupying liver lesion patients, were retrospectively included in this study. The three methods — one semiautomatic 3DMIA, one automatic ASM‐based, and one automatic PA‐based liver volumetry — achieved an accuracy with VD (volume difference) of − 1.69 %, − 2.75 %, and 3.06% in the normal group, respectively, and with VD of − 3.20 %, − 3.35 %, and 4.14% in the space‐occupying lesion group, respectively. However, the three methods achieved an efficiency of 27.63 mins, 1.26 mins, 1.18 mins on average, respectively, compared with the manual volumetry, which took 43.98 mins. The high intraclass correlation coefficient between the three methods and the manual method indicated an excellent agreement on liver volumetry. Significant differences in segmentation time were observed between the three methods (3DMIA, ASM, and PA) and the manual volumetry ( p < 0.001 ), as well as between the automatic volumetries (ASM and PA) and the semiautomatic volumetry (3DMIA) ( p < 0.001 ). The semiautomatic interactive 3DMIA, automatic ASM‐based, and automatic PA‐based liverAbstract : This study was to evaluate the accuracy, consistency, and efficiency of three liver volumetry methods— one interactive method, an in‐house‐developed 3D medical Image Analysis (3DMIA) system, one automatic active shape model (ASM)‐based segmentation, and one automatic probabilistic atlas (PA)‐guided segmentation method on clinical contrast‐enhanced CT images. Forty‐two datasets, including 27 normal liver and 15 space‐occupying liver lesion patients, were retrospectively included in this study. The three methods — one semiautomatic 3DMIA, one automatic ASM‐based, and one automatic PA‐based liver volumetry — achieved an accuracy with VD (volume difference) of − 1.69 %, − 2.75 %, and 3.06% in the normal group, respectively, and with VD of − 3.20 %, − 3.35 %, and 4.14% in the space‐occupying lesion group, respectively. However, the three methods achieved an efficiency of 27.63 mins, 1.26 mins, 1.18 mins on average, respectively, compared with the manual volumetry, which took 43.98 mins. The high intraclass correlation coefficient between the three methods and the manual method indicated an excellent agreement on liver volumetry. Significant differences in segmentation time were observed between the three methods (3DMIA, ASM, and PA) and the manual volumetry ( p < 0.001 ), as well as between the automatic volumetries (ASM and PA) and the semiautomatic volumetry (3DMIA) ( p < 0.001 ). The semiautomatic interactive 3DMIA, automatic ASM‐based, and automatic PA‐based liver volumetry agreed well with manual gold standard in both the normal liver group and the space‐occupying lesion group. The ASM‐ and PA‐based automatic segmentation have better efficiency in clinical use. PACS number(s): 87.55.‐x … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 17:Number 6(2016)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 17:Number 6(2016)
- Issue Display:
- Volume 17, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 6
- Issue Sort Value:
- 2016-0017-0006-0000
- Page Start:
- 118
- Page End:
- 127
- Publication Date:
- 2016-11-08
- Subjects:
- liver volumetry -- CT image -- image segmentation -- evaluation
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v17i6.6485 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2068.xml