Helical tomotherapy to LINAC plan conversion utilizing RayStation Fallback planning. (January 2017)
- Record Type:
- Journal Article
- Title:
- Helical tomotherapy to LINAC plan conversion utilizing RayStation Fallback planning. (January 2017)
- Main Title:
- Helical tomotherapy to LINAC plan conversion utilizing RayStation Fallback planning
- Authors:
- Zhang, Xin
Penagaricano, Jose
Narayanasamy, Ganesh
Corry, Peter
Liu, TianXiao
Sanjay, Maraboyina
Paudel, Nava
Morrill, Steven - Abstract:
- Abstract: RaySearch RayStation Fallback (FB) planning module can generate an equivalent backup radiotherapy treatment plan facilitating treatment on other linear accelerators. FB plans were generated from the RayStation FB module by simulating the original plan target and organ at risk (OAR) dose distribution and delivered in various backup linear accelerators. In this study, helical tomotherapy (HT) backup plans used in Varian TrueBeam linear accelerator were generated with the RayStation FB module. About 30 patients, 10 with lung cancer, 10 with head and neck (HN) cancer, and 10 with prostate cancer, who were treated with HT, were included in this study. Intensity‐modulated radiotherapy Fallback plans (FB‐IMRT) were generated for all patients, and three‐dimensional conformal radiotherapy Fallback plans (FB‐3D) were only generated for lung cancer patients. Dosimetric comparison study evaluated FB plans based on dose coverage to 95% of the PTV volume (R95 ), PTV mean dose (D mean ), Paddick's conformity index (CI), and dose homogeneity index (HI). The evaluation results showed that all IMRT plans were statistically comparable between HT and FB‐IMRT plans except that PTV HI was worse in prostate, and PTV R95 and HI were worse in HN multitarget plans for FB‐IMRT plans. For 3D lung cancer plans, only the PTV R95 was statistically comparable between HT and FB‐3D plans, PTV Dmean was higher, and CI and HI were worse compared to HT plans. The FB plans using a TrueBeam linearAbstract: RaySearch RayStation Fallback (FB) planning module can generate an equivalent backup radiotherapy treatment plan facilitating treatment on other linear accelerators. FB plans were generated from the RayStation FB module by simulating the original plan target and organ at risk (OAR) dose distribution and delivered in various backup linear accelerators. In this study, helical tomotherapy (HT) backup plans used in Varian TrueBeam linear accelerator were generated with the RayStation FB module. About 30 patients, 10 with lung cancer, 10 with head and neck (HN) cancer, and 10 with prostate cancer, who were treated with HT, were included in this study. Intensity‐modulated radiotherapy Fallback plans (FB‐IMRT) were generated for all patients, and three‐dimensional conformal radiotherapy Fallback plans (FB‐3D) were only generated for lung cancer patients. Dosimetric comparison study evaluated FB plans based on dose coverage to 95% of the PTV volume (R95 ), PTV mean dose (D mean ), Paddick's conformity index (CI), and dose homogeneity index (HI). The evaluation results showed that all IMRT plans were statistically comparable between HT and FB‐IMRT plans except that PTV HI was worse in prostate, and PTV R95 and HI were worse in HN multitarget plans for FB‐IMRT plans. For 3D lung cancer plans, only the PTV R95 was statistically comparable between HT and FB‐3D plans, PTV Dmean was higher, and CI and HI were worse compared to HT plans. The FB plans using a TrueBeam linear accelerator generally offer better OAR sparing compared to HT plans for all the patients. In this study, all cases of FB‐IMRT plans and 9/10 cases of FB‐3D plans were clinically acceptable without further modification and optimization once the FB plans were generated. However, the statistical differences between HT and FB‐IMRT/3D plans might not be of any clinically significant. One FB‐3D plan failed to simulate the original plan without further optimization. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 18:Number 1(2017)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 18:Number 1(2017)
- Issue Display:
- Volume 18, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 1
- Issue Sort Value:
- 2017-0018-0001-0000
- Page Start:
- 178
- Page End:
- 185
- Publication Date:
- 2017-01
- Subjects:
- dosimetric comparison -- Fallback treatment planning -- helical tomotherapy -- RayStation
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12032 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1255.xml