Modeling and dosimetric performance evaluation of the RayStation treatment planning system. (8th September 2014)
- Record Type:
- Journal Article
- Title:
- Modeling and dosimetric performance evaluation of the RayStation treatment planning system. (8th September 2014)
- Main Title:
- Modeling and dosimetric performance evaluation of the RayStation treatment planning system
- Authors:
- Mzenda, Bongile
Mugabe, Koki V.
Sims, Rick
Godwin, Guy
Loria, Dayan - Abstract:
- Abstract : The physics modeling, dose calculation accuracy and plan quality assessment of the RayStation (v3.5) treatment planning system (TPS) is presented in this study, with appropriate comparisons to the more established Pinnacle (v9.2) TPS. Modeling and validation for the Elekta MLCi and Agility beam models resulted in a good match to treatment machine‐measured data based on tolerances of 3% for in‐field and out‐of‐field regions, 10% for buildup and penumbral regions, and a gamma 2%/2 mm dose/distance acceptance criteria. TPS commissioning using a wide range of appropriately selected dosimetry equipment, and following published guidelines, established the MLC modeling and dose calculation accuracy to be within standard tolerances for all tests performed. In both homogeneous and heterogeneous mediums, central axis calculations agreed with measurements within 2% for open fields and 3% for wedged fields, and within 4% off‐axis. Treatment plan comparisons for identical clinical goals were made to Pinnacle for the following complex clinical cases: hypofractionated non‐small cell lung carcinoma, head and neck, stereotactic spine, as well as for several standard clinical cases comprising of prostate, brain, and breast plans. DVHs, target, and critical organ doses, as well as measured point doses and gamma indices, applying both local and global (Van Dyk) normalization at 2%/2 mm and 3%/3 mm (10% lower threshold) acceptance criteria for these composite plans were assessed. InAbstract : The physics modeling, dose calculation accuracy and plan quality assessment of the RayStation (v3.5) treatment planning system (TPS) is presented in this study, with appropriate comparisons to the more established Pinnacle (v9.2) TPS. Modeling and validation for the Elekta MLCi and Agility beam models resulted in a good match to treatment machine‐measured data based on tolerances of 3% for in‐field and out‐of‐field regions, 10% for buildup and penumbral regions, and a gamma 2%/2 mm dose/distance acceptance criteria. TPS commissioning using a wide range of appropriately selected dosimetry equipment, and following published guidelines, established the MLC modeling and dose calculation accuracy to be within standard tolerances for all tests performed. In both homogeneous and heterogeneous mediums, central axis calculations agreed with measurements within 2% for open fields and 3% for wedged fields, and within 4% off‐axis. Treatment plan comparisons for identical clinical goals were made to Pinnacle for the following complex clinical cases: hypofractionated non‐small cell lung carcinoma, head and neck, stereotactic spine, as well as for several standard clinical cases comprising of prostate, brain, and breast plans. DVHs, target, and critical organ doses, as well as measured point doses and gamma indices, applying both local and global (Van Dyk) normalization at 2%/2 mm and 3%/3 mm (10% lower threshold) acceptance criteria for these composite plans were assessed. In addition 3DVH was used to compare the perturbed dose distributions to the TPS 3D dose distributions. For all 32 cases, the patients QA checks showed > 95 % of pixels passing 3% global/3 mm gamma. PACS numbers: 87.55kd, 87.55km, 87.55de, 87.55dk … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 15:Number 5(2014)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 15:Number 5(2014)
- Issue Display:
- Volume 15, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 5
- Issue Sort Value:
- 2014-0015-0005-0000
- Page Start:
- 29
- Page End:
- 46
- Publication Date:
- 2014-09-08
- Subjects:
- dosimetric accuracy -- treatment planning system -- commissioning -- modeling
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v15i5.4787 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1070.xml