Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback. (8th March 2015)
- Record Type:
- Journal Article
- Title:
- Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback. (8th March 2015)
- Main Title:
- Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback
- Authors:
- Nakamura, Mitsuhiro
Akimoto, Mami
Ono, Tomohiro
Nakamura, Akira
Kishi, Takahiro
Yano, Shinsuke
Nakata, Manabu
Itasaka, Satoshi
Mizowaki, Takashi
Shibuya, Keiko
Hiraoka, Masahiro - Abstract:
- Abstract : We assessed interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography at end‐exhalation (EE) with visual feedback (BH‐CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity‐modulated radiation therapy with visual feedback were enrolled. All participating patients stopped oral intake, with the exception of drugs and water, for > 3 hr before treatment planning and daily treatment. Each patient was fixed in the supine position on an individualized vacuum pillow. An isotropic margin of 5 mm was added to the clinical target volume to create the planning target volume (PTV). The prescription dose was 42 to 51 Gy in 15 fractions. After correcting initial setup errors based on bony anatomy, the first BH‐CBCT scans were performed before beam delivery in every fraction. BH‐CBCT acquisition was obtained in three or four times breath holds by interrupting the acquisition two or three times, depending on the patient's BH ability. The image acquisition time for a 360° gantry rotation was approximately 90 s, including the interruption time due to BH. The initial setup errors were corrected based on bony structure, and the residual errors in the target position were then recorded. The magnitude of the interruptions variation in target position was assessed for 165 fractions. The systematic and random errors were 1.2 and 1.8 mm, 1.1 and 1.8 mm, and 1.7 and 2.9 mm in the left–right (LR),Abstract : We assessed interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography at end‐exhalation (EE) with visual feedback (BH‐CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity‐modulated radiation therapy with visual feedback were enrolled. All participating patients stopped oral intake, with the exception of drugs and water, for > 3 hr before treatment planning and daily treatment. Each patient was fixed in the supine position on an individualized vacuum pillow. An isotropic margin of 5 mm was added to the clinical target volume to create the planning target volume (PTV). The prescription dose was 42 to 51 Gy in 15 fractions. After correcting initial setup errors based on bony anatomy, the first BH‐CBCT scans were performed before beam delivery in every fraction. BH‐CBCT acquisition was obtained in three or four times breath holds by interrupting the acquisition two or three times, depending on the patient's BH ability. The image acquisition time for a 360° gantry rotation was approximately 90 s, including the interruption time due to BH. The initial setup errors were corrected based on bony structure, and the residual errors in the target position were then recorded. The magnitude of the interruptions variation in target position was assessed for 165 fractions. The systematic and random errors were 1.2 and 1.8 mm, 1.1 and 1.8 mm, and 1.7 and 2.9 mm in the left–right (LR), anterior–posterior (AP), and superior–inferior (SI) directions, respectively. Absolute interfraction variations of > 5 mm were observed in 18 fractions (11.0%) from seven patients because of EE‐BH failure. In conclusion, target matching is required to correct interfraction variation even with visual feedback, especially to ensure safe delivery of escalated doses to patients with pancreatic cancer. PACS number: 87.57.Q‐, 87.57.‐s, 87.55.Qr … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 16:Number 2(2015)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 16:Number 2(2015)
- Issue Display:
- Volume 16, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 2
- Issue Sort Value:
- 2015-0016-0002-0000
- Page Start:
- 108
- Page End:
- 116
- Publication Date:
- 2015-03-08
- Subjects:
- pancreatic cancer -- breath‐hold cone‐beam computed tomography -- visual feedback -- interfraction positional variation
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v16i2.5123 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1346.xml