Radiation dose reduction in thoracic and abdomen–pelvic CT using tube current modulation: a phantom study. (8th January 2014)
- Record Type:
- Journal Article
- Title:
- Radiation dose reduction in thoracic and abdomen–pelvic CT using tube current modulation: a phantom study. (8th January 2014)
- Main Title:
- Radiation dose reduction in thoracic and abdomen–pelvic CT using tube current modulation: a phantom study
- Authors:
- Sabarudin, Akmal
Mustafa, Zakira
Nassir, Khadijah Mohd
Hamid, Hamzaini Abdul
Sun, Zhonghua - Abstract:
- Abstract : This phantom study was designed to compare the radiation dose in thoracic and abdomen–pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size‐specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter‐100 (TLD‐100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen–pelvic CT. With use of TCM, the ED was 6.50 ± 0.29 mSv for thoracic and 6.01 ± 0.20 mSv for the abdomen–pelvic CT protocols. However without use of TCM, the ED was 20.07 ± 0.24 mSv and 17.30 ± 0.41 mSv for the thoracic and abdomen–pelvic CT protocols, respectively. The corresponding SSDE was 10.18 ± 0.48 mGy and 11.96 ± 0.27 mGy for the thoracic and abdomen–pelvic CT protocols with TCM, and 31.56 ± 0.43 mGy and 33.23 ± 0.05 mGy for thoracic and abdomen–pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58 ± 0.12 mGy in the TCM protocols and 51.52 ± 14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen–pelvic CT, the absorbed dose was highest at the skin with 9.30 ± 1.28 mGy and 29.99 ± 2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen–pelvic CT. PACS numbers:Abstract : This phantom study was designed to compare the radiation dose in thoracic and abdomen–pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size‐specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter‐100 (TLD‐100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen–pelvic CT. With use of TCM, the ED was 6.50 ± 0.29 mSv for thoracic and 6.01 ± 0.20 mSv for the abdomen–pelvic CT protocols. However without use of TCM, the ED was 20.07 ± 0.24 mSv and 17.30 ± 0.41 mSv for the thoracic and abdomen–pelvic CT protocols, respectively. The corresponding SSDE was 10.18 ± 0.48 mGy and 11.96 ± 0.27 mGy for the thoracic and abdomen–pelvic CT protocols with TCM, and 31.56 ± 0.43 mGy and 33.23 ± 0.05 mGy for thoracic and abdomen–pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58 ± 0.12 mGy in the TCM protocols and 51.52 ± 14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen–pelvic CT, the absorbed dose was highest at the skin with 9.30 ± 1.28 mGy and 29.99 ± 2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen–pelvic CT. PACS numbers: 87.57.Q‐, 87.57.qp, 87.53.Bn … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 16:Number 1(2015)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 16:Number 1(2015)
- Issue Display:
- Volume 16, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2015-0016-0001-0000
- Page Start:
- 319
- Page End:
- 328
- Publication Date:
- 2014-01-08
- Subjects:
- computed tomography -- tube current modulation -- radiation dose -- dose reduction
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v16i1.5135 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1199.xml