Comparison of pediatric radiation dose and vessel visibility on angiographic systems using piglets as a surrogate: antiscatter grid removal vs. lower detector air kerma settings with a grid — a preclinical investigation. (8th September 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of pediatric radiation dose and vessel visibility on angiographic systems using piglets as a surrogate: antiscatter grid removal vs. lower detector air kerma settings with a grid — a preclinical investigation. (8th September 2015)
- Main Title:
- Comparison of pediatric radiation dose and vessel visibility on angiographic systems using piglets as a surrogate: antiscatter grid removal vs. lower detector air kerma settings with a grid — a preclinical investigation
- Authors:
- Strauss, Keith J.
Racadio, John M.
Abruzzo, Todd A.
Johnson, Neil D.
Patel, Manish N.
Kukreja, Kamlesh U.
den Hartog, Mark. J. H.
Hoornaert, Bart P.A.
Nachabe, Rami A. - Abstract:
- Abstract : The purpose of this study was to reduce pediatric doses while maintaining or improving image quality scores without removing the grid from X‐ray beam. This study was approved by the Institutional Animal Care and Use Committee. Three piglets (5, 14, and 20 kg) were imaged using six different selectable detector air kerma ( K air ) per frame values (100%, 70%, 50%, 35%, 25%, 17.5%) with and without the grid. Number of distal branches visualized with diagnostic confidence relative to the injected vessel defined image quality score. Five pediatric interventional radiologists evaluated all images. Image quality score and piglet K air were statistically compared using analysis of variance and receiver operating curve analysis to define the preferred dose setting and use of grid for a visibility of 2nd and 3rd order vessel branches. Grid removal reduced both dose to subject and imaging quality by 26%. Third order branches could only be visualized with the grid present; 100% detector K air was required for smallest pig, while 70% detector K air was adequate for the two larger pigs. Second order branches could be visualized with grid at 17.5% detector K air for all three pig sizes. Without the grid, 50%, 35%, and 35% detector K air were required for smallest to largest pig, respectively. Grid removal reduces both dose and image quality score. Image quality scores can be maintained with less dose to subject with the grid in the beam as opposed to removed. Smaller anatomyAbstract : The purpose of this study was to reduce pediatric doses while maintaining or improving image quality scores without removing the grid from X‐ray beam. This study was approved by the Institutional Animal Care and Use Committee. Three piglets (5, 14, and 20 kg) were imaged using six different selectable detector air kerma ( K air ) per frame values (100%, 70%, 50%, 35%, 25%, 17.5%) with and without the grid. Number of distal branches visualized with diagnostic confidence relative to the injected vessel defined image quality score. Five pediatric interventional radiologists evaluated all images. Image quality score and piglet K air were statistically compared using analysis of variance and receiver operating curve analysis to define the preferred dose setting and use of grid for a visibility of 2nd and 3rd order vessel branches. Grid removal reduced both dose to subject and imaging quality by 26%. Third order branches could only be visualized with the grid present; 100% detector K air was required for smallest pig, while 70% detector K air was adequate for the two larger pigs. Second order branches could be visualized with grid at 17.5% detector K air for all three pig sizes. Without the grid, 50%, 35%, and 35% detector K air were required for smallest to largest pig, respectively. Grid removal reduces both dose and image quality score. Image quality scores can be maintained with less dose to subject with the grid in the beam as opposed to removed. Smaller anatomy requires more dose to the detector to achieve the same image quality score. PACS numbers: 87.53.Bn, 87.57.N‐, 87.57.cj, 87.59.cf, 87.59.Dj … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 16:Number 5(2015)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 16:Number 5(2015)
- Issue Display:
- Volume 16, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 5
- Issue Sort Value:
- 2015-0016-0005-0000
- Page Start:
- 408
- Page End:
- 417
- Publication Date:
- 2015-09-08
- Subjects:
- antiscatter grid -- radiation dose -- image quality -- pediatric
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v16i5.5379 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2700.xml