Estimation of patient setup uncertainty using BrainLAB Exatrac X‐Ray 6D system in image‐guided radiotherapy. (8th March 2015)
- Record Type:
- Journal Article
- Title:
- Estimation of patient setup uncertainty using BrainLAB Exatrac X‐Ray 6D system in image‐guided radiotherapy. (8th March 2015)
- Main Title:
- Estimation of patient setup uncertainty using BrainLAB Exatrac X‐Ray 6D system in image‐guided radiotherapy
- Authors:
- Infusino, Erminia
Trodella, Lucio
Ramella, Sara
D'Angelillo, Rolando M.
Greco, Carlo
Iurato, Aurelia
Trodella, Luca E.
Nacca, Alessandro
Cornacchione, Patrizia
Mameli, Alessandra - Abstract:
- Abstract : The purpose of this study was to evaluate setup uncertainties for brain sites with ExacTrac X‐Ray 6D system and to provide optimal margin guidelines. Fifteen patients with brain tumor were included in this study. Two X‐ray images with ExacTrac X‐Ray 6D system were used to verify patient position and tumor target localization before each treatment. The 6D fusion software first generates various sets of DRRs with position variations in both three translational and three rotational directions (six degrees of freedom) for the CT images. Setup variations (translation and rotation) after correction were recorded and corrected before treatment. The 3D deviations are expressed as mean ± standard deviation . The random error ( Σ ( σ i ) ), systematic error ( μ i ), and group systematic error ( M ( μ i ) ) for the different X‐ray were calculated using the definitions of van Herk. (1) Mean setup errors were calculated from X‐ray images acquired after all fractions. There is moderate patient‐to‐patient variation in the vertical direction and small variations in systematic errors and magnitudes of random errors are smaller. The global systematic errors were measured to be less than 2.0 mm in each direction. Random component of all patients are smaller ranging from 0.1–0.3 mm small. The safety margin (SM) to the lateral, is 0.5 mm and 2.6 mm for van Herk (1) and Stroom et al., (2) respectively, craniocaudal axis is 1.5 mm and 3.4 mm, respectively, and with respect to theAbstract : The purpose of this study was to evaluate setup uncertainties for brain sites with ExacTrac X‐Ray 6D system and to provide optimal margin guidelines. Fifteen patients with brain tumor were included in this study. Two X‐ray images with ExacTrac X‐Ray 6D system were used to verify patient position and tumor target localization before each treatment. The 6D fusion software first generates various sets of DRRs with position variations in both three translational and three rotational directions (six degrees of freedom) for the CT images. Setup variations (translation and rotation) after correction were recorded and corrected before treatment. The 3D deviations are expressed as mean ± standard deviation . The random error ( Σ ( σ i ) ), systematic error ( μ i ), and group systematic error ( M ( μ i ) ) for the different X‐ray were calculated using the definitions of van Herk. (1) Mean setup errors were calculated from X‐ray images acquired after all fractions. There is moderate patient‐to‐patient variation in the vertical direction and small variations in systematic errors and magnitudes of random errors are smaller. The global systematic errors were measured to be less than 2.0 mm in each direction. Random component of all patients are smaller ranging from 0.1–0.3 mm small. The safety margin (SM) to the lateral, is 0.5 mm and 2.6 mm for van Herk (1) and Stroom et al., (2) respectively, craniocaudal axis is 1.5 mm and 3.4 mm, respectively, and with respect to the antero–posterior axis, 2.3 mm and 3.9 mm. Daily X‐ray imaging is essential to compare and assess the accuracy of treatment delivery to different anatomical locations. PACS number: 87.55.D … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 16:Number 2(2015)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 16:Number 2(2015)
- Issue Display:
- Volume 16, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 2
- Issue Sort Value:
- 2015-0016-0002-0000
- Page Start:
- 99
- Page End:
- 107
- Publication Date:
- 2015-03-08
- Subjects:
- setup errors -- image‐guided radiotherapy -- X‐ray images -- infrared system -- treatment planning
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v16i2.5102 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1346.xml