Impact of dose calculation accuracy during optimization on lung IMRT plan quality. (8th January 2015)
- Record Type:
- Journal Article
- Title:
- Impact of dose calculation accuracy during optimization on lung IMRT plan quality. (8th January 2015)
- Main Title:
- Impact of dose calculation accuracy during optimization on lung IMRT plan quality
- Authors:
- Li, Ying
Rodrigues, Anna
Li, Taoran
Yuan, Lulin
Yin, Fang‐Fang
Wu, Q. Jackie - Abstract:
- Abstract : The purpose of this study was to evaluate the effect of dose calculation accuracy and the use of an intermediate dose calculation step during the optimization of intensity‐modulated radiation therapy (IMRT) planning on the final plan quality for lung cancer patients. This study included replanning for 11 randomly selected free‐breathing lung IMRT plans. The original plans were optimized using a fast pencil beam convolution algorithm. After optimization, the final dose calculation was performed using the analytical anisotropic algorithm (AAA). The Varian Treatment Planning System (TPS) Eclipse v11, includes an option to perform intermediate dose calculation during optimization using the AAA. The new plans were created using this intermediate dose calculation during optimization with the same planning objectives and dose constraints as in the original plan. Differences in dosimetric parameters for the planning target volume (PTV) dose coverage, organs‐at‐risk (OARs) dose sparing, and the number of monitor units (MU) between the original and new plans were analyzed. Statistical significance was determined with a p‐value of less than 0.05. All plans were normalized to cover 95% of the PTV with the prescription dose. Compared with the original plans, the PTV in the new plans had on average a lower maximum dose (69.45 vs. 71.96 Gy, p = 0.005 ), a better homogeneity index (HI) (0.08 vs. 0.12, p = 0.002 ), and a better conformity index (CI) (0.69 vs. 0.59, p = 0.003 ). InAbstract : The purpose of this study was to evaluate the effect of dose calculation accuracy and the use of an intermediate dose calculation step during the optimization of intensity‐modulated radiation therapy (IMRT) planning on the final plan quality for lung cancer patients. This study included replanning for 11 randomly selected free‐breathing lung IMRT plans. The original plans were optimized using a fast pencil beam convolution algorithm. After optimization, the final dose calculation was performed using the analytical anisotropic algorithm (AAA). The Varian Treatment Planning System (TPS) Eclipse v11, includes an option to perform intermediate dose calculation during optimization using the AAA. The new plans were created using this intermediate dose calculation during optimization with the same planning objectives and dose constraints as in the original plan. Differences in dosimetric parameters for the planning target volume (PTV) dose coverage, organs‐at‐risk (OARs) dose sparing, and the number of monitor units (MU) between the original and new plans were analyzed. Statistical significance was determined with a p‐value of less than 0.05. All plans were normalized to cover 95% of the PTV with the prescription dose. Compared with the original plans, the PTV in the new plans had on average a lower maximum dose (69.45 vs. 71.96 Gy, p = 0.005 ), a better homogeneity index (HI) (0.08 vs. 0.12, p = 0.002 ), and a better conformity index (CI) (0.69 vs. 0.59, p = 0.003 ). In the new plans, lung sparing was increased as the volumes receiving 5, 10, and 30 Gy were reduced when compared to the original plans (40.39% vs. 42.73%, p = 0.005 ; 28.93% vs. 30.40%, p = 0.001 ; 14.11% vs. 14.84%, p = 0.031 ). The volume receiving 20 Gy was not significantly lower (19.60% vs. 20.38%, p = 0.052 ). Further, the mean dose to the lung was reduced in the new plans (11.55 vs. 12.12 Gy, p = 0.024 ). For the esophagus, the mean dose, the maximum dose, and the volumes receiving 20 and 60 Gy were lower in the new plans than in the original plans (17.91 vs. 19.24 Gy, p = 0.004 ; 57.32 vs. 59.81 Gy, p = 0.020 ; 39.34% vs. 41.59%, p = 0.097 ; 12.56% vs. 15.35%, p = 0.101 ). For the heart, the mean dose, the maximum dose, and the volume receiving 40 Gy were also lower in new plans (11.07 vs. 12.04 Gy, p = 0.007 ; 56.41 vs. 57.7 Gy, p = 0.027 ; 7.16% vs. 9.37%, p = 0.012 ). The maximum dose to the spinal cord in the new plans was significantly lower than in the original IMRT plans (29.1 vs. 31.39 Gy, p = 0.014 ). Difference in MU between the IMRT plans was not significant (1216.90 vs. 1198.91, p = 0.328 ). In comparison to the original plans, the number of iterations needed to meet the optimization objectives in the new plans was reduced by a factor of 2 (2–3 vs. 5–6 iterations). Further, optimization was 30% faster corresponding to an average time savings of 10–15 min for the reoptimized plans. Accuracy of the dose calculation algorithm during optimization has an impact on planning efficiency, as well as on the final plan dosimetric quality. For lung IMRT treatment planning, utilizing the intermediate dose calculation during optimization is feasible for dose homogeneity improvement of the PTV and for improvement of optimization efficiency. PACS numbers: 87.55.D‐, 87.55.de, 87.55.dk … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 16:Number 1(2015)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 16:Number 1(2015)
- Issue Display:
- Volume 16, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2015-0016-0001-0000
- Page Start:
- 219
- Page End:
- 228
- Publication Date:
- 2015-01-08
- Subjects:
- lung cancer -- intensity‐modulated radiation therapy -- dose calculation algorithm -- optimization, treatment planning
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v16i1.5137 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1199.xml