Dosimetric review of cardiac implantable electronic device patients receiving radiotherapy. (8th January 2015)
- Record Type:
- Journal Article
- Title:
- Dosimetric review of cardiac implantable electronic device patients receiving radiotherapy. (8th January 2015)
- Main Title:
- Dosimetric review of cardiac implantable electronic device patients receiving radiotherapy
- Authors:
- Prisciandaro, Joann I.
Makkar, Akash
Fox, Colleen J.
Hayman, James A.
Horwood, Laura
Pelosi, Frank
Moran, Jean M. - Abstract:
- Abstract : A formal communication process was established and evaluated for the management of patients with cardiac implantable electronic devices (CIEDs) receiving radiation therapy (RT). Methods to estimate dose to the CIED were evaluated for their appropriateness in the management of these patients. A retrospective, institutional review board (IRB) approved study of 69 patients with CIEDs treated with RT between 2005 and 2011 was performed. The treatment sites, techniques, and the estimated doses to the CIEDs were analyzed and compared to estimates from published peripheral dose (PD) data and three treatment planning systems (TPSs) — UMPlan, Eclipse's AAA and Acuros algorithms. When measurements were indicated, radiation doses to the CIEDs ranged from 0.01–5.06 Gy. Total peripheral dose estimates based on publications differed from TLD measurements by an average of 0.94 Gy (0.05–4.49 Gy) and 0.51 Gy (0–2.74 Gy) for CIEDs within 2.5 cm and between 2.5 and 10 cm of the treatment field edge, respectively. Total peripheral dose estimates based on three TPSs differed from measurements by an average of 0.69 Gy (0.02–3.72 Gy) for CIEDs within 2.5 cm of the field edge. Of the 69 patients evaluated in this study, only two with defibrillators experienced a partial reset of their device during treatment. Based on this study, few CIED‐related events were observed during RT. The only noted correlation with treatment parameters for these two events was beam energy, as both patientsAbstract : A formal communication process was established and evaluated for the management of patients with cardiac implantable electronic devices (CIEDs) receiving radiation therapy (RT). Methods to estimate dose to the CIED were evaluated for their appropriateness in the management of these patients. A retrospective, institutional review board (IRB) approved study of 69 patients with CIEDs treated with RT between 2005 and 2011 was performed. The treatment sites, techniques, and the estimated doses to the CIEDs were analyzed and compared to estimates from published peripheral dose (PD) data and three treatment planning systems (TPSs) — UMPlan, Eclipse's AAA and Acuros algorithms. When measurements were indicated, radiation doses to the CIEDs ranged from 0.01–5.06 Gy. Total peripheral dose estimates based on publications differed from TLD measurements by an average of 0.94 Gy (0.05–4.49 Gy) and 0.51 Gy (0–2.74 Gy) for CIEDs within 2.5 cm and between 2.5 and 10 cm of the treatment field edge, respectively. Total peripheral dose estimates based on three TPSs differed from measurements by an average of 0.69 Gy (0.02–3.72 Gy) for CIEDs within 2.5 cm of the field edge. Of the 69 patients evaluated in this study, only two with defibrillators experienced a partial reset of their device during treatment. Based on this study, few CIED‐related events were observed during RT. The only noted correlation with treatment parameters for these two events was beam energy, as both patients were treated with high‐energy photon beams (16 MV). Differences in estimated and measured CIED doses were observed when using published PD data and TPS calculations. As such, we continue to follow conservative guidelines and measure CIED doses when the device is within 10 cm of the field or the estimated dose is greater than 2 Gy for pacemakers or 1 Gy for defibrillators. PACS number: 87.55.N‐ … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 16:Number 1(2015)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 16:Number 1(2015)
- Issue Display:
- Volume 16, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2015-0016-0001-0000
- Page Start:
- 254
- Page End:
- 263
- Publication Date:
- 2015-01-08
- Subjects:
- cardiac implantable electronic device -- pacemaker -- defibrillator -- radiation therapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v16i1.5189 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1198.xml