Simulation on the performance of ejector in a parallel hybrid ejector-based refrigerator-freezer cooling cycle. (1st July 2017)
- Record Type:
- Journal Article
- Title:
- Simulation on the performance of ejector in a parallel hybrid ejector-based refrigerator-freezer cooling cycle. (1st July 2017)
- Main Title:
- Simulation on the performance of ejector in a parallel hybrid ejector-based refrigerator-freezer cooling cycle
- Authors:
- Hou, Wenxiu
Wang, Lei
Yan, Jia
Li, Xianbi
Wang, Ling - Abstract:
- Highlights: A parallel hybrid ejector-based refrigerator-freezer cooling cycle is established. Simulation is conducted to seek optimum ejector geometric parameters. An adjustable ejector with a spindle is proposed to meet variable cooling loads. The effect of blocking percentage of nozzle on ejector performance is investigated. The effect of back pressure on the adjustable ejector performance is identified. Abstract: In this paper, the simulation is carried out to investigate the performance of ejector used in a parallel hybrid ejector-based refrigerator-freezer cooling cycle. The geometric parameters such as primary nozzle diameter, area ratio and constant-pressure mixing chamber length are studied firstly to achieve a good performance of the fixed area ratio ejector under a certain condition. Based on the obtained ejector geometry, an adjustable ejector with a spindle is used in the system to meet the requirements of variable cooling loads. The results show that the effect of blocking percentage of primary nozzle with a spindle on the ejector performance is considerable. Moreover, the adjustable ejector works well with relatively high entrainment ratio when the back pressure increment percentage as compared to the secondary flow pressure is no less than 16.15%.
- Is Part Of:
- Energy conversion and management. Volume 143(2017)
- Journal:
- Energy conversion and management
- Issue:
- Volume 143(2017)
- Issue Display:
- Volume 143, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 143
- Issue:
- 2017
- Issue Sort Value:
- 2017-0143-2017-0000
- Page Start:
- 440
- Page End:
- 447
- Publication Date:
- 2017-07-01
- Subjects:
- Variable area ratio ejector -- Entrainment ratio -- Back pressure -- Ejector-based refrigerator-freezer system -- Blocking percentage
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2017.04.030 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2272.xml